From 638e1672d49a1e623bee9a9cc50fc5cf5870f173 Mon Sep 17 00:00:00 2001 From: Giuseppe Bilotta Date: Thu, 8 Feb 2018 20:14:24 +0100 Subject: [PATCH] Don't clobber speed when reporting an invalid value Set the default _after_ printing the original value. --- src/acecad.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/src/acecad.c b/src/acecad.c index 09fb403..90eebe7 100644 --- a/src/acecad.c +++ b/src/acecad.c @@ -413,8 +413,8 @@ AceCadPreInit(InputDriverPtr drv, InputInfoPtr local, int flags) break; default: priv->acecadReportSpeed = 'R'; - speed = 85; xf86Msg(X_ERROR, "%s: ReportSpeed value %d invalid. Possible values: 120, 85, 10, 2. Defaulting to 85\n", local->name, speed); + speed = 85; msgtype = X_DEFAULT; } -- 2.32.0.93.g670b81a890