Merge branch 'block-dir' of git://brick.kernel.dk/data/git/linux-2.6-block
[linux-2.6] / drivers / md / Kconfig
1 #
2 # Block device driver configuration
3 #
4
5 menu "Multi-device support (RAID and LVM)"
6
7 config MD
8         bool "Multiple devices driver support (RAID and LVM)"
9         help
10           Support multiple physical spindles through a single logical device.
11           Required for RAID and logical volume management.
12
13 config BLK_DEV_MD
14         tristate "RAID support"
15         depends on MD
16         ---help---
17           This driver lets you combine several hard disk partitions into one
18           logical block device. This can be used to simply append one
19           partition to another one or to combine several redundant hard disks
20           into a RAID1/4/5 device so as to provide protection against hard
21           disk failures. This is called "Software RAID" since the combining of
22           the partitions is done by the kernel. "Hardware RAID" means that the
23           combining is done by a dedicated controller; if you have such a
24           controller, you do not need to say Y here.
25
26           More information about Software RAID on Linux is contained in the
27           Software RAID mini-HOWTO, available from
28           <http://www.tldp.org/docs.html#howto>. There you will also learn
29           where to get the supporting user space utilities raidtools.
30
31           If unsure, say N.
32
33 config MD_LINEAR
34         tristate "Linear (append) mode"
35         depends on BLK_DEV_MD
36         ---help---
37           If you say Y here, then your multiple devices driver will be able to
38           use the so-called linear mode, i.e. it will combine the hard disk
39           partitions by simply appending one to the other.
40
41           To compile this as a module, choose M here: the module
42           will be called linear.
43
44           If unsure, say Y.
45
46 config MD_RAID0
47         tristate "RAID-0 (striping) mode"
48         depends on BLK_DEV_MD
49         ---help---
50           If you say Y here, then your multiple devices driver will be able to
51           use the so-called raid0 mode, i.e. it will combine the hard disk
52           partitions into one logical device in such a fashion as to fill them
53           up evenly, one chunk here and one chunk there. This will increase
54           the throughput rate if the partitions reside on distinct disks.
55
56           Information about Software RAID on Linux is contained in the
57           Software-RAID mini-HOWTO, available from
58           <http://www.tldp.org/docs.html#howto>. There you will also
59           learn where to get the supporting user space utilities raidtools.
60
61           To compile this as a module, choose M here: the module
62           will be called raid0.
63
64           If unsure, say Y.
65
66 config MD_RAID1
67         tristate "RAID-1 (mirroring) mode"
68         depends on BLK_DEV_MD
69         ---help---
70           A RAID-1 set consists of several disk drives which are exact copies
71           of each other.  In the event of a mirror failure, the RAID driver
72           will continue to use the operational mirrors in the set, providing
73           an error free MD (multiple device) to the higher levels of the
74           kernel.  In a set with N drives, the available space is the capacity
75           of a single drive, and the set protects against a failure of (N - 1)
76           drives.
77
78           Information about Software RAID on Linux is contained in the
79           Software-RAID mini-HOWTO, available from
80           <http://www.tldp.org/docs.html#howto>.  There you will also
81           learn where to get the supporting user space utilities raidtools.
82
83           If you want to use such a RAID-1 set, say Y.  To compile this code
84           as a module, choose M here: the module will be called raid1.
85
86           If unsure, say Y.
87
88 config MD_RAID10
89         tristate "RAID-10 (mirrored striping) mode (EXPERIMENTAL)"
90         depends on BLK_DEV_MD && EXPERIMENTAL
91         ---help---
92           RAID-10 provides a combination of striping (RAID-0) and
93           mirroring (RAID-1) with easier configuration and more flexable
94           layout.
95           Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
96           be the same size (or at least, only as much as the smallest device
97           will be used).
98           RAID-10 provides a variety of layouts that provide different levels
99           of redundancy and performance.
100
101           RAID-10 requires mdadm-1.7.0 or later, available at:
102
103           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
104
105           If unsure, say Y.
106
107 config MD_RAID5
108         tristate "RAID-4/RAID-5 mode"
109         depends on BLK_DEV_MD
110         ---help---
111           A RAID-5 set of N drives with a capacity of C MB per drive provides
112           the capacity of C * (N - 1) MB, and protects against a failure
113           of a single drive. For a given sector (row) number, (N - 1) drives
114           contain data sectors, and one drive contains the parity protection.
115           For a RAID-4 set, the parity blocks are present on a single drive,
116           while a RAID-5 set distributes the parity across the drives in one
117           of the available parity distribution methods.
118
119           Information about Software RAID on Linux is contained in the
120           Software-RAID mini-HOWTO, available from
121           <http://www.tldp.org/docs.html#howto>. There you will also
122           learn where to get the supporting user space utilities raidtools.
123
124           If you want to use such a RAID-4/RAID-5 set, say Y.  To
125           compile this code as a module, choose M here: the module
126           will be called raid5.
127
128           If unsure, say Y.
129
130 config MD_RAID6
131         tristate "RAID-6 mode"
132         depends on BLK_DEV_MD
133         ---help---
134           A RAID-6 set of N drives with a capacity of C MB per drive
135           provides the capacity of C * (N - 2) MB, and protects
136           against a failure of any two drives. For a given sector
137           (row) number, (N - 2) drives contain data sectors, and two
138           drives contains two independent redundancy syndromes.  Like
139           RAID-5, RAID-6 distributes the syndromes across the drives
140           in one of the available parity distribution methods.
141
142           RAID-6 requires mdadm-1.5.0 or later, available at:
143
144           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
145
146           If you want to use such a RAID-6 set, say Y.  To compile
147           this code as a module, choose M here: the module will be
148           called raid6.
149
150           If unsure, say Y.
151
152 config MD_MULTIPATH
153         tristate "Multipath I/O support"
154         depends on BLK_DEV_MD
155         help
156           Multipath-IO is the ability of certain devices to address the same
157           physical disk over multiple 'IO paths'. The code ensures that such
158           paths can be defined and handled at runtime, and ensures that a
159           transparent failover to the backup path(s) happens if a IO errors
160           arrives on the primary path.
161
162           If unsure, say N.
163
164 config MD_FAULTY
165         tristate "Faulty test module for MD"
166         depends on BLK_DEV_MD
167         help
168           The "faulty" module allows for a block device that occasionally returns
169           read or write errors.  It is useful for testing.
170
171           In unsure, say N.
172
173 config BLK_DEV_DM
174         tristate "Device mapper support"
175         depends on MD
176         ---help---
177           Device-mapper is a low level volume manager.  It works by allowing
178           people to specify mappings for ranges of logical sectors.  Various
179           mapping types are available, in addition people may write their own
180           modules containing custom mappings if they wish.
181
182           Higher level volume managers such as LVM2 use this driver.
183
184           To compile this as a module, choose M here: the module will be
185           called dm-mod.
186
187           If unsure, say N.
188
189 config DM_CRYPT
190         tristate "Crypt target support"
191         depends on BLK_DEV_DM && EXPERIMENTAL
192         select CRYPTO
193         ---help---
194           This device-mapper target allows you to create a device that
195           transparently encrypts the data on it. You'll need to activate
196           the ciphers you're going to use in the cryptoapi configuration.
197
198           Information on how to use dm-crypt can be found on
199
200           <http://www.saout.de/misc/dm-crypt/>
201
202           To compile this code as a module, choose M here: the module will
203           be called dm-crypt.
204
205           If unsure, say N.
206
207 config DM_SNAPSHOT
208        tristate "Snapshot target (EXPERIMENTAL)"
209        depends on BLK_DEV_DM && EXPERIMENTAL
210        ---help---
211          Allow volume managers to take writeable snapshots of a device.
212
213 config DM_MIRROR
214        tristate "Mirror target (EXPERIMENTAL)"
215        depends on BLK_DEV_DM && EXPERIMENTAL
216        ---help---
217          Allow volume managers to mirror logical volumes, also
218          needed for live data migration tools such as 'pvmove'.
219
220 config DM_ZERO
221         tristate "Zero target (EXPERIMENTAL)"
222         depends on BLK_DEV_DM && EXPERIMENTAL
223         ---help---
224           A target that discards writes, and returns all zeroes for
225           reads.  Useful in some recovery situations.
226
227 config DM_MULTIPATH
228         tristate "Multipath target (EXPERIMENTAL)"
229         depends on BLK_DEV_DM && EXPERIMENTAL
230         ---help---
231           Allow volume managers to support multipath hardware.
232
233 config DM_MULTIPATH_EMC
234         tristate "EMC CX/AX multipath support (EXPERIMENTAL)"
235         depends on DM_MULTIPATH && BLK_DEV_DM && EXPERIMENTAL
236         ---help---
237           Multipath support for EMC CX/AX series hardware.
238
239 endmenu
240