Merge git://git.infradead.org/mtd-2.6
[linux-2.6] / Documentation / hwmon / f71882fg
1 Kernel driver f71882fg
2 ======================
3
4 Supported chips:
5   * Fintek F71882FG and F71883FG
6     Prefix: 'f71882fg'
7     Addresses scanned: none, address read from Super I/O config space
8     Datasheet: Available from the Fintek website
9   * Fintek F71862FG and F71863FG
10     Prefix: 'f71862fg'
11     Addresses scanned: none, address read from Super I/O config space
12     Datasheet: Available from the Fintek website
13   * Fintek F8000
14     Prefix: 'f8000'
15     Addresses scanned: none, address read from Super I/O config space
16     Datasheet: Not public
17
18 Author: Hans de Goede <hdegoede@redhat.com>
19
20
21 Description
22 -----------
23
24 Fintek F718xxFG/F8000 Super I/O chips include complete hardware monitoring
25 capabilities. They can monitor up to 9 voltages (3 for the F8000), 4 fans and
26 3 temperature sensors.
27
28 These chips also have fan controlling features, using either DC or PWM, in
29 three different modes (one manual, two automatic).
30
31 The driver assumes that no more than one chip is present, which seems
32 reasonable.
33
34
35 Monitoring
36 ----------
37
38 The Voltage, Fan and Temperature Monitoring uses the standard sysfs
39 interface as documented in sysfs-interface, without any exceptions.
40
41
42 Fan Control
43 -----------
44
45 Both PWM (pulse-width modulation) and DC fan speed control methods are
46 supported. The right one to use depends on external circuitry on the
47 motherboard, so the driver assumes that the BIOS set the method
48 properly.
49
50 There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC
51 voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM
52 mode where the actual RPM of the fan (as measured) is controlled and the speed
53 gets specified as 0-100% of the fan#_full_speed file.
54
55 Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a
56 whole lot of a difference when modifying fan control settings. The only
57 important difference is that in RPM mode the 0-100% controls the fan speed
58 between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs
59 RPM mode, it will also set fan#_full_speed properly, if it does not then
60 fan control will not work properly, unless you set a sane fan#_full_speed
61 value yourself.
62
63 Switching between these modes requires re-initializing a whole bunch of
64 registers, so the mode which the BIOS has set is kept. The mode is
65 printed when loading the driver.
66
67 Three different fan control modes are supported; the mode number is written
68 to the pwm#_enable file. Note that not all modes are supported on all
69 chips, and some modes may only be available in RPM / PWM mode on the F8000.
70 Writing an unsupported mode will result in an invalid parameter error.
71
72 * 1: Manual mode
73   You ask for a specific PWM duty cycle / DC voltage or a specific % of
74   fan#_full_speed by writing to the pwm# file. This mode is only
75   available on the F8000 if the fan channel is in RPM mode.
76
77 * 2: Normal auto mode
78   You can define a number of temperature/fan speed trip points, which % the
79   fan should run at at this temp and which temp a fan should follow using the
80   standard sysfs interface. The number and type of trip points is chip
81   depended, see which files are available in sysfs.
82   Fan/PWM channel 3 of the F8000 is always in this mode!
83
84 * 3: Thermostat mode (Only available on the F8000 when in duty cycle mode)
85   The fan speed is regulated to keep the temp the fan is mapped to between
86   temp#_auto_point2_temp and temp#_auto_point3_temp.
87
88 Both of the automatic modes require that pwm1 corresponds to fan1, pwm2 to
89 fan2 and pwm3 to fan3.