Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/sparc-2.6
[linux-2.6] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config RAID_ATTRS
4         tristate "RAID Transport Class"
5         default n
6         depends on BLOCK
7         ---help---
8           Provides RAID
9
10 config SCSI
11         tristate "SCSI device support"
12         depends on BLOCK
13         select SCSI_DMA if HAS_DMA
14         ---help---
15           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
16           any other SCSI device under Linux, say Y and make sure that you know
17           the name of your SCSI host adapter (the card inside your computer
18           that "speaks" the SCSI protocol, also called SCSI controller),
19           because you will be asked for it.
20
21           You also need to say Y here if you have a device which speaks
22           the SCSI protocol.  Examples of this include the parallel port
23           version of the IOMEGA ZIP drive, USB storage devices, Fibre
24           Channel, FireWire storage and the IDE-SCSI emulation driver.
25
26           To compile this driver as a module, choose M here and read
27           <file:Documentation/scsi/scsi.txt>.
28           The module will be called scsi_mod.
29
30           However, do not compile this as a module if your root file system
31           (the one containing the directory /) is located on a SCSI device.
32
33 config SCSI_DMA
34         bool
35         default n
36
37 config SCSI_TGT
38         tristate "SCSI target support"
39         depends on SCSI && EXPERIMENTAL
40         ---help---
41           If you want to use SCSI target mode drivers enable this option.
42           If you choose M, the module will be called scsi_tgt.
43
44 config SCSI_NETLINK
45         bool
46         default n
47         select NET
48
49 config SCSI_PROC_FS
50         bool "legacy /proc/scsi/ support"
51         depends on SCSI && PROC_FS
52         default y
53         ---help---
54           This option enables support for the various files in
55           /proc/scsi.  In Linux 2.6 this has been superseded by
56           files in sysfs but many legacy applications rely on this.
57
58           If unsure say Y.
59
60 comment "SCSI support type (disk, tape, CD-ROM)"
61         depends on SCSI
62
63 config BLK_DEV_SD
64         tristate "SCSI disk support"
65         depends on SCSI
66         ---help---
67           If you want to use SCSI hard disks, Fibre Channel disks,
68           Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
69           USB storage or the SCSI or parallel port version of
70           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
71           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
72           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
73           CD-ROMs.
74
75           To compile this driver as a module, choose M here and read
76           <file:Documentation/scsi/scsi.txt>.
77           The module will be called sd_mod.
78
79           Do not compile this driver as a module if your root file system
80           (the one containing the directory /) is located on a SCSI disk.
81           In this case, do not compile the driver for your SCSI host adapter
82           (below) as a module either.
83
84 config CHR_DEV_ST
85         tristate "SCSI tape support"
86         depends on SCSI
87         ---help---
88           If you want to use a SCSI tape drive under Linux, say Y and read the
89           SCSI-HOWTO, available from
90           <http://www.tldp.org/docs.html#howto>, and
91           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
92           for SCSI CD-ROMs.
93
94           To compile this driver as a module, choose M here and read
95           <file:Documentation/scsi/scsi.txt>. The module will be called st.
96
97 config CHR_DEV_OSST
98         tristate "SCSI OnStream SC-x0 tape support"
99         depends on SCSI
100         ---help---
101           The OnStream SC-x0 SCSI tape drives cannot be driven by the
102           standard st driver, but instead need this special osst driver and
103           use the  /dev/osstX char device nodes (major 206).  Via usb-storage
104           and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
105           as well.  Note that there is also a second generation of OnStream
106           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
107           tapes (QIC-157) and can be driven by the standard driver st.
108           For more information, you may have a look at the SCSI-HOWTO
109           <http://www.tldp.org/docs.html#howto>  and
110           <file:Documentation/scsi/osst.txt>  in the kernel source.
111           More info on the OnStream driver may be found on
112           <http://linux1.onstream.nl/test/>
113           Please also have a look at the standard st docu, as most of it
114           applies to osst as well.
115
116           To compile this driver as a module, choose M here and read
117           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
118
119 config BLK_DEV_SR
120         tristate "SCSI CDROM support"
121         depends on SCSI
122         ---help---
123           If you want to use a SCSI or FireWire CD-ROM under Linux,
124           say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
125           <http://www.tldp.org/docs.html#howto>. Also make sure to say
126           Y or M to "ISO 9660 CD-ROM file system support" later.
127
128           To compile this driver as a module, choose M here and read
129           <file:Documentation/scsi/scsi.txt>.
130           The module will be called sr_mod.
131
132 config BLK_DEV_SR_VENDOR
133         bool "Enable vendor-specific extensions (for SCSI CDROM)"
134         depends on BLK_DEV_SR
135         help
136           This enables the usage of vendor specific SCSI commands. This is
137           required to support multisession CDs with old NEC/TOSHIBA cdrom
138           drives (and HP Writers). If you have such a drive and get the first
139           session only, try saying Y here; everybody else says N.
140
141 config CHR_DEV_SG
142         tristate "SCSI generic support"
143         depends on SCSI
144         ---help---
145           If you want to use SCSI scanners, synthesizers or CD-writers or just
146           about anything having "SCSI" in its name other than hard disks,
147           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
148           directly, so you need some additional software which knows how to
149           talk to these devices using the SCSI protocol:
150
151           For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
152           writer software look at Cdrtools
153           (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
154           and for burning a "disk at once": CDRDAO
155           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
156           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
157           For other devices, it's possible that you'll have to write the
158           driver software yourself. Please read the file
159           <file:Documentation/scsi/scsi-generic.txt> for more information.
160
161           To compile this driver as a module, choose M here and read
162           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
163
164           If unsure, say N.
165
166 config CHR_DEV_SCH
167         tristate "SCSI media changer support"
168         depends on SCSI
169         ---help---
170           This is a driver for SCSI media changers.  Most common devices are
171           tape libraries and MOD/CDROM jukeboxes.  *Real* jukeboxes, you
172           don't need this for those tiny 6-slot cdrom changers.  Media
173           changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
174           If you have such hardware and want to use it with linux, say Y
175           here.  Check <file:Documentation/scsi/scsi-changer.txt> for details.
176         
177           If you want to compile this as a module ( = code which can be
178           inserted in and removed from the running kernel whenever you want),
179           say M here and read <file:Documentation/kbuild/modules.txt> and
180           <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
181           If unsure, say N.
182
183 config SCSI_ENCLOSURE
184         tristate "SCSI Enclosure Support"
185         depends on SCSI && ENCLOSURE_SERVICES
186         help
187           Enclosures are devices sitting on or in SCSI backplanes that
188           manage devices.  If you have a disk cage, the chances are that
189           it has an enclosure device.  Selecting this option will just allow
190           certain enclosure conditions to be reported and is not required.
191
192 comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
193         depends on SCSI
194
195 config SCSI_MULTI_LUN
196         bool "Probe all LUNs on each SCSI device"
197         depends on SCSI
198         help
199           If you have a SCSI device that supports more than one LUN (Logical
200           Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
201           can say Y here to force the SCSI driver to probe for multiple LUNs.
202           A SCSI device with multiple LUNs acts logically like multiple SCSI
203           devices. The vast majority of SCSI devices have only one LUN, and
204           so most people can say N here. The max_luns boot/module parameter 
205           allows to override this setting.
206
207 config SCSI_CONSTANTS
208         bool "Verbose SCSI error reporting (kernel size +=12K)"
209         depends on SCSI
210         help
211           The error messages regarding your SCSI hardware will be easier to
212           understand if you say Y here; it will enlarge your kernel by about
213           12 KB. If in doubt, say Y.
214
215 config SCSI_LOGGING
216         bool "SCSI logging facility"
217         depends on SCSI
218         ---help---
219           This turns on a logging facility that can be used to debug a number
220           of SCSI related problems.
221
222           If you say Y here, no logging output will appear by default, but you
223           can enable logging by saying Y to "/proc file system support" and
224           "Sysctl support" below and executing the command
225
226           echo "scsi log token [level]" > /proc/scsi/scsi
227
228           at boot time after the /proc file system has been mounted.
229
230           There are a number of things that can be used for 'token' (you can
231           find them in the source: <file:drivers/scsi/scsi.c>), and this
232           allows you to select the types of information you want, and the
233           level allows you to select the level of verbosity.
234
235           If you say N here, it may be harder to track down some types of SCSI
236           problems. If you say Y here your kernel will be somewhat larger, but
237           there should be no noticeable performance impact as long as you have
238           logging turned off.
239
240 config SCSI_SCAN_ASYNC
241         bool "Asynchronous SCSI scanning"
242         depends on SCSI
243         help
244           The SCSI subsystem can probe for devices while the rest of the
245           system continues booting, and even probe devices on different
246           busses in parallel, leading to a significant speed-up.
247
248           If you have built SCSI as modules, enabling this option can
249           be a problem as the devices may not have been found by the
250           time your system expects them to have been.  You can load the
251           scsi_wait_scan module to ensure that all scans have completed.
252           If you build your SCSI drivers into the kernel, then everything
253           will work fine if you say Y here.
254
255           You can override this choice by specifying "scsi_mod.scan=sync"
256           or async on the kernel's command line.
257
258 config SCSI_WAIT_SCAN
259         tristate
260         default m
261         depends on SCSI
262         depends on MODULES
263
264 menu "SCSI Transports"
265         depends on SCSI
266
267 config SCSI_SPI_ATTRS
268         tristate "Parallel SCSI (SPI) Transport Attributes"
269         depends on SCSI
270         help
271           If you wish to export transport-specific information about
272           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
273
274 config SCSI_FC_ATTRS
275         tristate "FiberChannel Transport Attributes"
276         depends on SCSI
277         select SCSI_NETLINK
278         help
279           If you wish to export transport-specific information about
280           each attached FiberChannel device to sysfs, say Y.
281           Otherwise, say N.
282
283 config SCSI_FC_TGT_ATTRS
284         bool "SCSI target support for FiberChannel Transport Attributes"
285         depends on SCSI_FC_ATTRS
286         depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
287         help
288                 If you want to use SCSI target mode drivers enable this option.
289
290 config SCSI_ISCSI_ATTRS
291         tristate "iSCSI Transport Attributes"
292         depends on SCSI && NET
293         help
294           If you wish to export transport-specific information about
295           each attached iSCSI device to sysfs, say Y.
296           Otherwise, say N.
297
298 config SCSI_SAS_ATTRS
299         tristate "SAS Transport Attributes"
300         depends on SCSI && BLK_DEV_BSG
301         help
302           If you wish to export transport-specific information about
303           each attached SAS device to sysfs, say Y.
304
305 source "drivers/scsi/libsas/Kconfig"
306
307 config SCSI_SRP_ATTRS
308         tristate "SRP Transport Attributes"
309         depends on SCSI
310         help
311           If you wish to export transport-specific information about
312           each attached SRP device to sysfs, say Y.
313
314 config SCSI_SRP_TGT_ATTRS
315         bool "SCSI target support for SRP Transport Attributes"
316         depends on SCSI_SRP_ATTRS
317         depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
318         help
319                 If you want to use SCSI target mode drivers enable this option.
320
321 endmenu
322
323 menuconfig SCSI_LOWLEVEL
324         bool "SCSI low-level drivers"
325         depends on SCSI!=n
326         default y
327
328 if SCSI_LOWLEVEL && SCSI
329
330 config ISCSI_TCP
331         tristate "iSCSI Initiator over TCP/IP"
332         depends on SCSI && INET
333         select CRYPTO
334         select CRYPTO_MD5
335         select CRYPTO_CRC32C
336         select SCSI_ISCSI_ATTRS
337         help
338          The iSCSI Driver provides a host with the ability to access storage
339          through an IP network. The driver uses the iSCSI protocol to transport
340          SCSI requests and responses over a TCP/IP network between the host
341          (the "initiator") and "targets".  Architecturally, the iSCSI driver
342          combines with the host's TCP/IP stack, network drivers, and Network
343          Interface Card (NIC) to provide the same functions as a SCSI or a
344          Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
345
346          To compile this driver as a module, choose M here: the
347          module will be called iscsi_tcp.
348
349          The userspace component needed to initialize the driver, documentation,
350          and sample configuration files can be found here:
351
352          http://open-iscsi.org
353
354 config SGIWD93_SCSI
355         tristate "SGI WD93C93 SCSI Driver"
356         depends on SGI_HAS_WD93 && SCSI
357         help
358           If you have a Western Digital WD93 SCSI controller on
359           an SGI MIPS system, say Y.  Otherwise, say N.
360
361 config BLK_DEV_3W_XXXX_RAID
362         tristate "3ware 5/6/7/8xxx ATA-RAID support"
363         depends on PCI && SCSI
364         help
365           3ware is the only hardware ATA-Raid product in Linux to date.
366           This card is 2,4, or 8 channel master mode support only.
367           SCSI support required!!!
368
369           <http://www.3ware.com/>
370
371           Please read the comments at the top of
372           <file:drivers/scsi/3w-xxxx.c>.
373
374 config SCSI_3W_9XXX
375         tristate "3ware 9xxx SATA-RAID support"
376         depends on PCI && SCSI
377         help
378           This driver supports the 9000 series 3ware SATA-RAID cards.
379
380           <http://www.amcc.com>
381
382           Please read the comments at the top of
383           <file:drivers/scsi/3w-9xxx.c>.
384
385 config SCSI_7000FASST
386         tristate "7000FASST SCSI support"
387         depends on ISA && SCSI && ISA_DMA_API
388         select CHECK_SIGNATURE
389         help
390           This driver supports the Western Digital 7000 SCSI host adapter
391           family.  Some information is in the source:
392           <file:drivers/scsi/wd7000.c>.
393
394           To compile this driver as a module, choose M here: the
395           module will be called wd7000.
396
397 config SCSI_ACARD
398         tristate "ACARD SCSI support"
399         depends on PCI && SCSI
400         help
401           This driver supports the ACARD SCSI host adapter.
402           Support Chip <ATP870 ATP876 ATP880 ATP885>
403           To compile this driver as a module, choose M here: the
404           module will be called atp870u.
405
406 config SCSI_AHA152X
407         tristate "Adaptec AHA152X/2825 support"
408         depends on ISA && SCSI && !64BIT
409         select SCSI_SPI_ATTRS
410         select CHECK_SIGNATURE
411         ---help---
412           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
413           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
414           must be manually specified in this case.
415
416           It is explained in section 3.3 of the SCSI-HOWTO, available from
417           <http://www.tldp.org/docs.html#howto>. You might also want to
418           read the file <file:Documentation/scsi/aha152x.txt>.
419
420           To compile this driver as a module, choose M here: the
421           module will be called aha152x.
422
423 config SCSI_AHA1542
424         tristate "Adaptec AHA1542 support"
425         depends on ISA && SCSI && ISA_DMA_API
426         ---help---
427           This is support for a SCSI host adapter.  It is explained in section
428           3.4 of the SCSI-HOWTO, available from
429           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
430           purchased by Adaptec, and some former Trantor products are being
431           sold under the Adaptec name.  If it doesn't work out of the box, you
432           may have to change some settings in <file:drivers/scsi/aha1542.h>.
433
434           To compile this driver as a module, choose M here: the
435           module will be called aha1542.
436
437 config SCSI_AHA1740
438         tristate "Adaptec AHA1740 support"
439         depends on EISA && SCSI
440         ---help---
441           This is support for a SCSI host adapter.  It is explained in section
442           3.5 of the SCSI-HOWTO, available from
443           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
444           of the box, you may have to change some settings in
445           <file:drivers/scsi/aha1740.h>.
446
447           To compile this driver as a module, choose M here: the
448           module will be called aha1740.
449
450 config SCSI_AACRAID
451         tristate "Adaptec AACRAID support"
452         depends on SCSI && PCI
453         help
454           This driver supports a variety of Dell, HP, Adaptec, IBM and
455           ICP storage products. For a list of supported products, refer
456           to <file:Documentation/scsi/aacraid.txt>.
457
458           To compile this driver as a module, choose M here: the module
459           will be called aacraid.
460
461
462 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
463
464 config SCSI_AIC7XXX_OLD
465         tristate "Adaptec AIC7xxx support (old driver)"
466         depends on (ISA || EISA || PCI ) && SCSI
467         help
468           WARNING This driver is an older aic7xxx driver and is no longer
469           under active development.  Adaptec, Inc. is writing a new driver to
470           take the place of this one, and it is recommended that whenever
471           possible, people should use the new Adaptec written driver instead
472           of this one.  This driver will eventually be phased out entirely.
473
474           This is support for the various aic7xxx based Adaptec SCSI
475           controllers. These include the 274x EISA cards; 284x VLB cards;
476           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
477           motherboard based SCSI controllers from Adaptec. It does not support
478           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
479           support them. It does not support the 2920 cards from Adaptec that
480           use the Future Domain SCSI controller chip. For those cards, you
481           need the "Future Domain 16xx SCSI support" driver.
482
483           In general, if the controller is based on an Adaptec SCSI controller
484           chip from the aic777x series or the aic78xx series, this driver
485           should work. The only exception is the 7810 which is specifically
486           not supported (that's the RAID controller chip on the AAA-13x
487           cards).
488
489           Note that the AHA2920 SCSI host adapter is *not* supported by this
490           driver; choose "Future Domain 16xx SCSI support" instead if you have
491           one of those.
492
493           Information on the configuration options for this controller can be
494           found by checking the help file for each of the available
495           configuration options. You should read
496           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
497           contacting the maintainer with any questions.  The SCSI-HOWTO,
498           available from <http://www.tldp.org/docs.html#howto>, can also
499           be of great help.
500
501           To compile this driver as a module, choose M here: the
502           module will be called aic7xxx_old.
503
504 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
505 source "drivers/scsi/aic94xx/Kconfig"
506
507 config SCSI_DPT_I2O
508         tristate "Adaptec I2O RAID support "
509         depends on SCSI && PCI && VIRT_TO_BUS
510         help
511           This driver supports all of Adaptec's I2O based RAID controllers as 
512           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
513           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
514
515           To compile this driver as a module, choose M here: the
516           module will be called dpt_i2o.
517
518 config SCSI_ADVANSYS
519         tristate "AdvanSys SCSI support"
520         depends on SCSI && VIRT_TO_BUS
521         depends on ISA || EISA || PCI
522         help
523           This is a driver for all SCSI host adapters manufactured by
524           AdvanSys. It is documented in the kernel source in
525           <file:drivers/scsi/advansys.c>.
526
527           To compile this driver as a module, choose M here: the
528           module will be called advansys.
529
530 config SCSI_IN2000
531         tristate "Always IN2000 SCSI support"
532         depends on ISA && SCSI
533         help
534           This is support for an ISA bus SCSI host adapter.  You'll find more
535           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
536           out of the box, you may have to change the jumpers for IRQ or
537           address selection.
538
539           To compile this driver as a module, choose M here: the
540           module will be called in2000.
541
542 config SCSI_ARCMSR
543         tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
544         depends on PCI && SCSI
545         help
546           This driver supports all of ARECA's SATA/SAS RAID controller cards.
547           This is an ARECA-maintained driver by Erich Chen.
548           If you have any problems, please mail to: <erich@areca.com.tw>.
549           Areca supports Linux RAID config tools.
550           Please link <http://www.areca.com.tw>
551
552           To compile this driver as a module, choose M here: the
553           module will be called arcmsr (modprobe arcmsr).
554
555 config SCSI_ARCMSR_AER
556         bool "Enable PCI Error Recovery Capability in Areca Driver(ARCMSR)"
557         depends on SCSI_ARCMSR && PCIEAER
558         default n
559         help
560           The advanced error reporting(AER) capability is "NOT" provided by
561           ARC1200/1201/1202 SATA RAID controllers cards.
562           If your card is one of ARC1200/1201/1202, please use the default setting, n.
563           If your card is other models, you could pick it
564           on condition that the kernel version is greater than 2.6.19.
565           This function is maintained driver by Nick Cheng. If you have any
566           problems or suggestion, you are welcome to contact with <nick.cheng@areca.com.tw>.
567           To enable this function, choose Y here.
568
569 source "drivers/scsi/megaraid/Kconfig.megaraid"
570
571 config SCSI_HPTIOP
572         tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
573         depends on SCSI && PCI
574         help
575           This option enables support for HighPoint RocketRAID 3xxx/4xxx
576           controllers.
577
578           To compile this driver as a module, choose M here; the module
579           will be called hptiop. If unsure, say N.
580
581 config SCSI_BUSLOGIC
582         tristate "BusLogic SCSI support"
583         depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
584         ---help---
585           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
586           Adapters. Consult the SCSI-HOWTO, available from
587           <http://www.tldp.org/docs.html#howto>, and the files
588           <file:Documentation/scsi/BusLogic.txt> and
589           <file:Documentation/scsi/FlashPoint.txt> for more information.
590           Note that support for FlashPoint is only available for 32-bit
591           x86 configurations.
592
593           To compile this driver as a module, choose M here: the
594           module will be called BusLogic.
595
596 config SCSI_FLASHPOINT
597         bool "FlashPoint support"
598         depends on SCSI_BUSLOGIC && PCI && X86_32
599         help
600           This option allows you to add FlashPoint support to the
601           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
602           substantial, so users of MultiMaster Host Adapters may not
603           wish to include it.
604
605 config SCSI_DMX3191D
606         tristate "DMX3191D SCSI support"
607         depends on PCI && SCSI
608         select SCSI_SPI_ATTRS
609         help
610           This is support for Domex DMX3191D SCSI Host Adapters.
611
612           To compile this driver as a module, choose M here: the
613           module will be called dmx3191d.
614
615 config SCSI_DTC3280
616         tristate "DTC3180/3280 SCSI support"
617         depends on ISA && SCSI
618         select SCSI_SPI_ATTRS
619         select CHECK_SIGNATURE
620         help
621           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
622           the SCSI-HOWTO, available from
623           <http://www.tldp.org/docs.html#howto>, and the file
624           <file:Documentation/scsi/dtc3x80.txt>.
625
626           To compile this driver as a module, choose M here: the
627           module will be called dtc.
628
629 config SCSI_EATA
630         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
631         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
632         ---help---
633           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
634           ISA and all EISA I/O addresses are probed looking for the "EATA"
635           signature. The addresses of all the PCI SCSI controllers reported
636           by the PCI subsystem are probed as well.
637
638           You want to read the start of <file:drivers/scsi/eata.c> and the
639           SCSI-HOWTO, available from
640           <http://www.tldp.org/docs.html#howto>.
641
642           To compile this driver as a module, choose M here: the
643           module will be called eata.
644
645 config SCSI_EATA_TAGGED_QUEUE
646         bool "enable tagged command queueing"
647         depends on SCSI_EATA
648         help
649           This is a feature of SCSI-2 which improves performance: the host
650           adapter can send several SCSI commands to a device's queue even if
651           previous commands haven't finished yet.
652           This is equivalent to the "eata=tc:y" boot option.
653
654 config SCSI_EATA_LINKED_COMMANDS
655         bool "enable elevator sorting"
656         depends on SCSI_EATA
657         help
658           This option enables elevator sorting for all probed SCSI disks and
659           CD-ROMs. It definitely reduces the average seek distance when doing
660           random seeks, but this does not necessarily result in a noticeable
661           performance improvement: your mileage may vary...
662           This is equivalent to the "eata=lc:y" boot option.
663
664 config SCSI_EATA_MAX_TAGS
665         int "maximum number of queued commands"
666         depends on SCSI_EATA
667         default "16"
668         help
669           This specifies how many SCSI commands can be maximally queued for
670           each probed SCSI device. You should reduce the default value of 16
671           only if you have disks with buggy or limited tagged command support.
672           Minimum is 2 and maximum is 62. This value is also the window size
673           used by the elevator sorting option above. The effective value used
674           by the driver for each probed SCSI device is reported at boot time.
675           This is equivalent to the "eata=mq:8" boot option.
676
677 config SCSI_EATA_PIO
678         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
679         depends on (ISA || EISA || PCI) && SCSI && BROKEN
680         ---help---
681           This driver supports all EATA-PIO protocol compliant SCSI Host
682           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
683           host adapters could also use this driver but are discouraged from
684           doing so, since this driver only supports hard disks and lacks
685           numerous features.  You might want to have a look at the SCSI-HOWTO,
686           available from <http://www.tldp.org/docs.html#howto>.
687
688           To compile this driver as a module, choose M here: the
689           module will be called eata_pio.
690
691 config SCSI_FUTURE_DOMAIN
692         tristate "Future Domain 16xx SCSI/AHA-2920A support"
693         depends on (ISA || PCI) && SCSI
694         select CHECK_SIGNATURE
695         ---help---
696           This is support for Future Domain's 16-bit SCSI host adapters
697           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
698           other adapters based on the Future Domain chipsets (Quantum
699           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
700           It is explained in section 3.7 of the SCSI-HOWTO, available from
701           <http://www.tldp.org/docs.html#howto>.
702
703           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
704           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
705           controller support"). This Future Domain driver works with the older
706           Adaptec AHA-2920A boards with a Future Domain chip on them.
707
708           To compile this driver as a module, choose M here: the
709           module will be called fdomain.
710
711 config SCSI_FD_MCS
712         tristate "Future Domain MCS-600/700 SCSI support"
713         depends on MCA_LEGACY && SCSI
714         ---help---
715           This is support for Future Domain MCS 600/700 MCA SCSI adapters.
716           Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
717           is identical to the MCS 700 and hence also supported by this driver.
718           This driver also supports the Reply SB16/SCSI card (the SCSI part).
719           It supports multiple adapters in the same system.
720
721           To compile this driver as a module, choose M here: the
722           module will be called fd_mcs.
723
724 config SCSI_GDTH
725         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
726         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
727         ---help---
728           Formerly called GDT SCSI Disk Array Controller Support.
729
730           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
731           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
732           in the kernel source in <file:drivers/scsi/gdth.c> and
733           <file:drivers/scsi/gdth.h>.
734
735           To compile this driver as a module, choose M here: the
736           module will be called gdth.
737
738 config SCSI_GENERIC_NCR5380
739         tristate "Generic NCR5380/53c400 SCSI PIO support"
740         depends on ISA && SCSI
741         select SCSI_SPI_ATTRS
742         ---help---
743           This is a driver for the old NCR 53c80 series of SCSI controllers
744           on boards using PIO. Most boards such as the Trantor T130 fit this
745           category, along with a large number of ISA 8bit controllers shipped
746           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
747           you should select the specific driver for that card rather than
748           generic 5380 support.
749
750           It is explained in section 3.8 of the SCSI-HOWTO, available from
751           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
752           of the box, you may have to change some settings in
753           <file:drivers/scsi/g_NCR5380.h>.
754
755           To compile this driver as a module, choose M here: the
756           module will be called g_NCR5380.
757
758 config SCSI_GENERIC_NCR5380_MMIO
759         tristate "Generic NCR5380/53c400 SCSI MMIO support"
760         depends on ISA && SCSI
761         select SCSI_SPI_ATTRS
762         ---help---
763           This is a driver for the old NCR 53c80 series of SCSI controllers
764           on boards using memory mapped I/O. 
765           It is explained in section 3.8 of the SCSI-HOWTO, available from
766           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
767           of the box, you may have to change some settings in
768           <file:drivers/scsi/g_NCR5380.h>.
769
770           To compile this driver as a module, choose M here: the
771           module will be called g_NCR5380_mmio.
772
773 config SCSI_GENERIC_NCR53C400
774         bool "Enable NCR53c400 extensions"
775         depends on SCSI_GENERIC_NCR5380
776         help
777           This enables certain optimizations for the NCR53c400 SCSI cards.
778           You might as well try it out.  Note that this driver will only probe
779           for the Trantor T130B in its default configuration; you might have
780           to pass a command line option to the kernel at boot time if it does
781           not detect your card.  See the file
782           <file:Documentation/scsi/g_NCR5380.txt> for details.
783
784 config SCSI_IBMMCA
785         tristate "IBMMCA SCSI support"
786         depends on MCA && SCSI
787         ---help---
788           This is support for the IBM SCSI adapter found in many of the PS/2
789           series computers.  These machines have an MCA bus, so you need to
790           answer Y to "MCA support" as well and read
791           <file:Documentation/mca.txt>.
792
793           If the adapter isn't found during boot (a common problem for models
794           56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
795           option, where <pun> is the id of the SCSI subsystem (usually 7, but
796           if that doesn't work check your reference diskette).  Owners of
797           model 95 with a LED-matrix-display can in addition activate some
798           activity info like under OS/2, but more informative, by setting
799           'ibmmcascsi=display' as an additional kernel parameter.  Try "man
800           bootparam" or see the documentation of your boot loader about how to
801           pass options to the kernel.
802
803           To compile this driver as a module, choose M here: the
804           module will be called ibmmca.
805
806 config IBMMCA_SCSI_ORDER_STANDARD
807         bool "Standard SCSI-order"
808         depends on SCSI_IBMMCA
809         ---help---
810           In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
811           are assigned to the drive letters, starting with the lowest SCSI-id
812           (physical number -- pun) to be drive C:, as seen from DOS and
813           similar operating systems. When looking into papers describing the
814           ANSI-SCSI-standard, this assignment of drives appears to be wrong.
815           The SCSI-standard follows a hardware-hierarchy which says that id 7
816           has the highest priority and id 0 the lowest. Therefore, the host
817           adapters are still today everywhere placed as SCSI-id 7 by default.
818           In the SCSI-standard, the drive letters express the priority of the
819           disk. C: should be the hard disk, or a partition on it, with the
820           highest priority. This must therefore be the disk with the highest
821           SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
822           original definition of the SCSI-standard as also industrial- and
823           process-control-machines, like VME-CPUs running under realtime-OSes
824           (e.g. LynxOS, OS9) do.
825
826           If you like to run Linux on your MCA-machine with the same
827           assignment of hard disks as seen from e.g. DOS or OS/2 on your
828           machine, which is in addition conformant to the SCSI-standard, you
829           must say Y here. This is also necessary for MCA-Linux users who want
830           to keep downward compatibility to older releases of the
831           IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
832           June 1997).
833
834           If you like to have the lowest SCSI-id assigned as drive C:, as
835           modern SCSI-BIOSes do, which does not conform to the standard, but
836           is widespread and common in the PC-world of today, you must say N
837           here. If unsure, say Y.
838
839 config IBMMCA_SCSI_DEV_RESET
840         bool "Reset SCSI-devices at boottime"
841         depends on SCSI_IBMMCA
842         ---help---
843           By default, SCSI-devices are reset when the machine is powered on.
844           However, some devices exist, like special-control-devices,
845           SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
846           not reset when switched on. If you say Y here, each device connected
847           to your SCSI-bus will be issued a reset-command after it has been
848           probed, while the kernel is booting. This may cause problems with
849           more modern devices, like hard disks, which do not appreciate these
850           reset commands, and can cause your system to hang. So say Y only if
851           you know that one of your older devices needs it; N is the safe
852           answer.
853
854 config SCSI_IPS
855         tristate "IBM ServeRAID support"
856         depends on PCI && SCSI
857         ---help---
858           This is support for the IBM ServeRAID hardware RAID controllers.
859           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
860           for more information.  If this driver does not work correctly
861           without modification please contact the author by email at
862           <ipslinux@adaptec.com>.
863
864           To compile this driver as a module, choose M here: the
865           module will be called ips.
866
867 config SCSI_IBMVSCSI
868         tristate "IBM Virtual SCSI support"
869         depends on PPC_PSERIES || PPC_ISERIES
870         select SCSI_SRP_ATTRS
871         help
872           This is the IBM POWER Virtual SCSI Client
873
874           To compile this driver as a module, choose M here: the
875           module will be called ibmvscsic.
876
877 config SCSI_IBMVSCSIS
878         tristate "IBM Virtual SCSI Server support"
879         depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
880         help
881           This is the SRP target driver for IBM pSeries virtual environments.
882
883           The userspace component needed to initialize the driver and
884           documentation can be found:
885
886           http://stgt.berlios.de/
887
888           To compile this driver as a module, choose M here: the
889           module will be called ibmvstgt.
890
891 config SCSI_INITIO
892         tristate "Initio 9100U(W) support"
893         depends on PCI && SCSI
894         help
895           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
896           read the SCSI-HOWTO, available from
897           <http://www.tldp.org/docs.html#howto>.
898
899           To compile this driver as a module, choose M here: the
900           module will be called initio.
901
902 config SCSI_INIA100
903         tristate "Initio INI-A100U2W support"
904         depends on PCI && SCSI
905         help
906           This is support for the Initio INI-A100U2W SCSI host adapter.
907           Please read the SCSI-HOWTO, available from
908           <http://www.tldp.org/docs.html#howto>.
909
910           To compile this driver as a module, choose M here: the
911           module will be called a100u2w.
912
913 config SCSI_PPA
914         tristate "IOMEGA parallel port (ppa - older drives)"
915         depends on SCSI && PARPORT_PC
916         ---help---
917           This driver supports older versions of IOMEGA's parallel port ZIP
918           drive (a 100 MB removable media device).
919
920           Note that you can say N here if you have the SCSI version of the ZIP
921           drive: it will be supported automatically if you said Y to the
922           generic "SCSI disk support", above.
923
924           If you have the ZIP Plus drive or a more recent parallel port ZIP
925           drive (if the supplied cable with the drive is labeled "AutoDetect")
926           then you should say N here and Y to "IOMEGA parallel port (imm -
927           newer drives)", below.
928
929           For more information about this driver and how to use it you should
930           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
931           the SCSI-HOWTO, which is available from
932           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
933           you will still be able to use the parallel port for other tasks,
934           such as a printer; it is safe to compile both drivers into the
935           kernel.
936
937           To compile this driver as a module, choose M here: the
938           module will be called ppa.
939
940 config SCSI_IMM
941         tristate "IOMEGA parallel port (imm - newer drives)"
942         depends on SCSI && PARPORT_PC
943         ---help---
944           This driver supports newer versions of IOMEGA's parallel port ZIP
945           drive (a 100 MB removable media device).
946
947           Note that you can say N here if you have the SCSI version of the ZIP
948           drive: it will be supported automatically if you said Y to the
949           generic "SCSI disk support", above.
950
951           If you have the ZIP Plus drive or a more recent parallel port ZIP
952           drive (if the supplied cable with the drive is labeled "AutoDetect")
953           then you should say Y here; if you have an older ZIP drive, say N
954           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
955
956           For more information about this driver and how to use it you should
957           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
958           the SCSI-HOWTO, which is available from
959           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
960           you will still be able to use the parallel port for other tasks,
961           such as a printer; it is safe to compile both drivers into the
962           kernel.
963
964           To compile this driver as a module, choose M here: the
965           module will be called imm.
966
967 config SCSI_IZIP_EPP16
968         bool "ppa/imm option - Use slow (but safe) EPP-16"
969         depends on SCSI_PPA || SCSI_IMM
970         ---help---
971           EPP (Enhanced Parallel Port) is a standard for parallel ports which
972           allows them to act as expansion buses that can handle up to 64
973           peripheral devices.
974
975           Some parallel port chipsets are slower than their motherboard, and
976           so we have to control the state of the chipset's FIFO queue every
977           now and then to avoid data loss. This will be done if you say Y
978           here.
979
980           Generally, saying Y is the safe option and slows things down a bit.
981
982 config SCSI_IZIP_SLOW_CTR
983         bool "ppa/imm option - Assume slow parport control register"
984         depends on SCSI_PPA || SCSI_IMM
985         help
986           Some parallel ports are known to have excessive delays between
987           changing the parallel port control register and good data being
988           available on the parallel port data/status register. This option
989           forces a small delay (1.0 usec to be exact) after changing the
990           control register to let things settle out. Enabling this option may
991           result in a big drop in performance but some very old parallel ports
992           (found in 386 vintage machines) will not work properly.
993
994           Generally, saying N is fine.
995
996 config SCSI_MVSAS
997         tristate "Marvell 88SE6440 SAS/SATA support"
998         depends on PCI && SCSI
999         select SCSI_SAS_LIBSAS
1000         help
1001           This driver supports Marvell SAS/SATA PCI devices.
1002
1003           To compiler this driver as a module, choose M here: the module
1004           will be called mvsas.
1005
1006 config SCSI_NCR53C406A
1007         tristate "NCR53c406a SCSI support"
1008         depends on ISA && SCSI
1009         help
1010           This is support for the NCR53c406a SCSI host adapter.  For user
1011           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
1012           in the kernel source.  Also read the SCSI-HOWTO, available from
1013           <http://www.tldp.org/docs.html#howto>.
1014
1015           To compile this driver as a module, choose M here: the
1016           module will be called NCR53c406.
1017
1018 config SCSI_NCR_D700
1019         tristate "NCR Dual 700 MCA SCSI support"
1020         depends on MCA && SCSI
1021         select SCSI_SPI_ATTRS
1022         help
1023           This is a driver for the MicroChannel Dual 700 card produced by
1024           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1025           tries to negotiate sync and uses tag command queueing.
1026
1027           Unless you have an NCR manufactured machine, the chances are that
1028           you do not have this SCSI card, so say N.
1029
1030 config SCSI_LASI700
1031         tristate "HP Lasi SCSI support for 53c700/710"
1032         depends on GSC && SCSI
1033         select SCSI_SPI_ATTRS
1034         help
1035           This is a driver for the SCSI controller in the Lasi chip found in
1036           many PA-RISC workstations & servers.  If you do not know whether you
1037           have a Lasi chip, it is safe to say "Y" here.
1038
1039 config SCSI_SNI_53C710
1040         tristate "SNI RM SCSI support for 53c710"
1041         depends on SNI_RM && SCSI
1042         select SCSI_SPI_ATTRS
1043         select 53C700_LE_ON_BE
1044         help
1045           This is a driver for the onboard SCSI controller found in older
1046           SNI RM workstations & servers.
1047
1048 config 53C700_LE_ON_BE
1049         bool
1050         depends on SCSI_LASI700
1051         default y
1052
1053 config SCSI_STEX
1054         tristate "Promise SuperTrak EX Series support"
1055         depends on PCI && SCSI
1056         ---help---
1057           This driver supports Promise SuperTrak EX series storage controllers.
1058
1059           Promise provides Linux RAID configuration utility for these
1060           controllers. Please visit <http://www.promise.com> to download.
1061
1062           To compile this driver as a module, choose M here: the
1063           module will be called stex.
1064
1065 config 53C700_BE_BUS
1066         bool
1067         depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1068         default y
1069
1070 config SCSI_SYM53C8XX_2
1071         tristate "SYM53C8XX Version 2 SCSI support"
1072         depends on PCI && SCSI
1073         select SCSI_SPI_ATTRS
1074         ---help---
1075           This driver supports the whole NCR53C8XX/SYM53C8XX family of
1076           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
1077           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1078           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1079           controllers; you need to use the Fusion MPT driver for that.
1080
1081           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1082           information.
1083
1084 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1085         int "DMA addressing mode"
1086         depends on SCSI_SYM53C8XX_2
1087         default "1"
1088         ---help---
1089           This option only applies to PCI-SCSI chips that are PCI DAC
1090           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1091
1092           When set to 0, the driver will program the chip to only perform
1093           32-bit DMA.  When set to 1, the chip will be able to perform DMA
1094           to addresses up to 1TB.  When set to 2, the driver supports the
1095           full 64-bit DMA address range, but can only address 16 segments
1096           of 4 GB each.  This limits the total addressable range to 64 GB.
1097
1098           Most machines with less than 4GB of memory should use a setting
1099           of 0 for best performance.  If your machine has 4GB of memory
1100           or more, you should set this option to 1 (the default).
1101
1102           The still experimental value 2 (64 bit DMA addressing with 16
1103           x 4GB segments limitation) can be used on systems that require
1104           PCI address bits past bit 39 to be set for the addressing of
1105           memory using PCI DAC cycles.
1106
1107 config SCSI_SYM53C8XX_DEFAULT_TAGS
1108         int "Default tagged command queue depth"
1109         depends on SCSI_SYM53C8XX_2
1110         default "16"
1111         help
1112           This is the default value of the command queue depth the
1113           driver will announce to the generic SCSI layer for devices
1114           that support tagged command queueing. This value can be changed
1115           from the boot command line.  This is a soft limit that cannot
1116           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1117
1118 config SCSI_SYM53C8XX_MAX_TAGS
1119         int "Maximum number of queued commands"
1120         depends on SCSI_SYM53C8XX_2
1121         default "64"
1122         help
1123           This option allows you to specify the maximum number of commands
1124           that can be queued to any device, when tagged command queuing is
1125           possible. The driver supports up to 256 queued commands per device.
1126           This value is used as a compiled-in hard limit.
1127
1128 config SCSI_SYM53C8XX_MMIO
1129         bool "Use memory mapped IO"
1130         depends on SCSI_SYM53C8XX_2
1131         default y
1132         help
1133           Memory mapped IO is faster than Port IO.  Most people should
1134           answer Y here, but some machines may have problems.  If you have
1135           to answer N here, please report the problem to the maintainer.
1136
1137 config SCSI_IPR
1138         tristate "IBM Power Linux RAID adapter support"
1139         depends on PCI && SCSI && ATA
1140         select FW_LOADER
1141         ---help---
1142           This driver supports the IBM Power Linux family RAID adapters.
1143           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1144           as IBM iSeries 5702, 5703, 5709, and 570A.
1145
1146 config SCSI_IPR_TRACE
1147         bool "enable driver internal trace"
1148         depends on SCSI_IPR
1149         default y
1150         help
1151           If you say Y here, the driver will trace all commands issued
1152           to the adapter. Performance impact is minimal. Trace can be
1153           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1154
1155 config SCSI_IPR_DUMP
1156         bool "enable adapter dump support"
1157         depends on SCSI_IPR
1158         default y
1159         help
1160           If you say Y here, the driver will support adapter crash dump.
1161           If you enable this support, the iprdump daemon can be used
1162           to capture adapter failure analysis information.
1163
1164 config SCSI_ZALON
1165         tristate "Zalon SCSI support"
1166         depends on GSC && SCSI
1167         select SCSI_SPI_ATTRS
1168         help
1169           The Zalon is a GSC/HSC bus interface chip that sits between the
1170           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1171           C110, J200, J210 and some D, K & R-class machines.  It's also
1172           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1173           Say Y here if you have one of these machines or cards.
1174
1175 config SCSI_NCR_Q720
1176         tristate "NCR Quad 720 MCA SCSI support"
1177         depends on MCA && SCSI
1178         select SCSI_SPI_ATTRS
1179         help
1180           This is a driver for the MicroChannel Quad 720 card produced by
1181           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1182           tries to negotiate sync and uses tag command queueing.
1183
1184           Unless you have an NCR manufactured machine, the chances are that
1185           you do not have this SCSI card, so say N.
1186
1187 config SCSI_NCR53C8XX_DEFAULT_TAGS
1188         int "default tagged command queue depth"
1189         depends on SCSI_ZALON || SCSI_NCR_Q720
1190         default "8"
1191         ---help---
1192           "Tagged command queuing" is a feature of SCSI-2 which improves
1193           performance: the host adapter can send several SCSI commands to a
1194           device's queue even if previous commands haven't finished yet.
1195           Because the device is intelligent, it can optimize its operations
1196           (like head positioning) based on its own request queue. Some SCSI
1197           devices don't implement this properly; if you want to disable this
1198           feature, enter 0 or 1 here (it doesn't matter which).
1199
1200           The default value is 8 and should be supported by most hard disks.
1201           This value can be overridden from the boot command line using the
1202           'tags' option as follows (example):
1203           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1204           4, set queue depth to 16 for target 2 and target 3 on controller 0
1205           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1206
1207           The normal answer therefore is to go with the default 8 and to use
1208           a boot command line option for devices that need to use a different
1209           command queue depth.
1210
1211           There is no safe option other than using good SCSI devices.
1212
1213 config SCSI_NCR53C8XX_MAX_TAGS
1214         int "maximum number of queued commands"
1215         depends on SCSI_ZALON || SCSI_NCR_Q720
1216         default "32"
1217         ---help---
1218           This option allows you to specify the maximum number of commands
1219           that can be queued to any device, when tagged command queuing is
1220           possible. The default value is 32. Minimum is 2, maximum is 64.
1221           Modern hard disks are able to support 64 tags and even more, but
1222           do not seem to be faster when more than 32 tags are being used.
1223
1224           So, the normal answer here is to go with the default value 32 unless
1225           you are using very large hard disks with large cache (>= 1 MB) that
1226           are able to take advantage of more than 32 tagged commands.
1227
1228           There is no safe option and the default answer is recommended.
1229
1230 config SCSI_NCR53C8XX_SYNC
1231         int "synchronous transfers frequency in MHz"
1232         depends on SCSI_ZALON || SCSI_NCR_Q720
1233         default "20"
1234         ---help---
1235           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1236           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1237           are respectively the maximum data transfer rates in mega-transfers
1238           per second for each class.  For example, a FAST-20 Wide 16 device is
1239           able to transfer data at 20 million 16 bit packets per second for a
1240           total rate of 40 MB/s.
1241
1242           You may specify 0 if you want to only use asynchronous data
1243           transfers. This is the safest and slowest option. Otherwise, specify
1244           a value between 5 and 80, depending on the capability of your SCSI
1245           controller.  The higher the number, the faster the data transfer.
1246           Note that 80 should normally be ok since the driver decreases the
1247           value automatically according to the controller's capabilities.
1248
1249           Your answer to this question is ignored for controllers with NVRAM,
1250           since the driver will get this information from the user set-up.  It
1251           also can be overridden using a boot setup option, as follows
1252           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1253           for FAST-20 synchronous data transfer (20 mega-transfers per
1254           second).
1255
1256           The normal answer therefore is not to go with the default but to
1257           select the maximum value 80 allowing the driver to use the maximum
1258           value supported by each controller. If this causes problems with
1259           your SCSI devices, you should come back and decrease the value.
1260
1261           There is no safe option other than using good cabling, right
1262           terminations and SCSI conformant devices.
1263
1264 config SCSI_NCR53C8XX_NO_DISCONNECT
1265         bool "not allow targets to disconnect"
1266         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1267         help
1268           This option is only provided for safety if you suspect some SCSI
1269           device of yours to not support properly the target-disconnect
1270           feature. In that case, you would say Y here. In general however, to
1271           not allow targets to disconnect is not reasonable if there is more
1272           than 1 device on a SCSI bus. The normal answer therefore is N.
1273
1274 config SCSI_PAS16
1275         tristate "PAS16 SCSI support"
1276         depends on ISA && SCSI
1277         select SCSI_SPI_ATTRS
1278         ---help---
1279           This is support for a SCSI host adapter.  It is explained in section
1280           3.10 of the SCSI-HOWTO, available from
1281           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1282           of the box, you may have to change some settings in
1283           <file:drivers/scsi/pas16.h>.
1284
1285           To compile this driver as a module, choose M here: the
1286           module will be called pas16.
1287
1288 config SCSI_QLOGIC_FAS
1289         tristate "Qlogic FAS SCSI support"
1290         depends on ISA && SCSI
1291         ---help---
1292           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1293           FastSCSI! cards as well as any other card based on the FASXX chip
1294           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1295
1296           This driver does NOT support the PCI versions of these cards. The
1297           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1298           SCSI support"), below.
1299
1300           Information about this driver is contained in
1301           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1302           SCSI-HOWTO, available from
1303           <http://www.tldp.org/docs.html#howto>.
1304
1305           To compile this driver as a module, choose M here: the
1306           module will be called qlogicfas.
1307
1308 config SCSI_QLOGIC_FC_FIRMWARE
1309         bool "Include loadable firmware in driver"
1310         depends on SCSI_QLOGIC_FC
1311         help
1312           Say Y to include ISP2X00 Fabric Initiator/Target Firmware, with
1313           expanded LUN addressing and FcTape (FCP-2) support, in the
1314           qlogicfc driver. This is required on some platforms.
1315
1316 config SCSI_QLOGIC_1280
1317         tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1318         depends on PCI && SCSI
1319         help
1320           Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1321
1322           To compile this driver as a module, choose M here: the
1323           module will be called qla1280.
1324
1325 config SCSI_QLOGICPTI
1326         tristate "PTI Qlogic, ISP Driver"
1327         depends on SBUS && SCSI
1328         help
1329           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1330           controllers are known under Solaris as qpti and in the openprom as
1331           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1332           driven by a different driver.
1333
1334           To compile this driver as a module, choose M here: the
1335           module will be called qlogicpti.
1336
1337 source "drivers/scsi/qla2xxx/Kconfig"
1338 source "drivers/scsi/qla4xxx/Kconfig"
1339
1340 config SCSI_LPFC
1341         tristate "Emulex LightPulse Fibre Channel Support"
1342         depends on PCI && SCSI
1343         select SCSI_FC_ATTRS
1344         help
1345           This lpfc driver supports the Emulex LightPulse
1346           Family of Fibre Channel PCI host adapters.
1347
1348 config SCSI_SIM710
1349         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1350         depends on (EISA || MCA) && SCSI
1351         select SCSI_SPI_ATTRS
1352         ---help---
1353           This driver for NCR53c710 based SCSI host adapters.
1354
1355           It currently supports Compaq EISA cards and NCR MCA cards
1356
1357 config SCSI_SYM53C416
1358         tristate "Symbios 53c416 SCSI support"
1359         depends on ISA && SCSI
1360         ---help---
1361           This is support for the sym53c416 SCSI host adapter, the SCSI
1362           adapter that comes with some HP scanners. This driver requires that
1363           the sym53c416 is configured first using some sort of PnP
1364           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1365           are using isapnp then you need to compile this driver as a module
1366           and then load it using insmod after isapnp has run. The parameters
1367           of the configured card(s) should be passed to the driver. The format
1368           is:
1369
1370           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1371
1372           To compile this driver as a module, choose M here: the
1373           module will be called sym53c416.
1374
1375 config SCSI_DC395x
1376         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1377         depends on PCI && SCSI && EXPERIMENTAL
1378         ---help---
1379           This driver supports PCI SCSI host adapters based on the ASIC
1380           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1381
1382           This driver works, but is still in experimental status. So better
1383           have a bootable disk and a backup in case of emergency.
1384
1385           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1386
1387           To compile this driver as a module, choose M here: the
1388           module will be called dc395x.
1389
1390 config SCSI_DC390T
1391         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1392         depends on PCI && SCSI
1393         ---help---
1394           This driver supports PCI SCSI host adapters based on the Am53C974A
1395           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1396           PCscsi/PCnet (Am53/79C974) solutions.
1397
1398           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1399
1400           Note that this driver does NOT support Tekram DC390W/U/F, which are
1401           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1402
1403           To compile this driver as a module, choose M here: the
1404           module will be called tmscsim.
1405
1406 config SCSI_T128
1407         tristate "Trantor T128/T128F/T228 SCSI support"
1408         depends on ISA && SCSI
1409         select SCSI_SPI_ATTRS
1410         select CHECK_SIGNATURE
1411         ---help---
1412           This is support for a SCSI host adapter. It is explained in section
1413           3.11 of the SCSI-HOWTO, available from
1414           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1415           of the box, you may have to change some settings in
1416           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1417           Adaptec, and some former Trantor products are being sold under the
1418           Adaptec name.
1419
1420           To compile this driver as a module, choose M here: the
1421           module will be called t128.
1422
1423 config SCSI_U14_34F
1424         tristate "UltraStor 14F/34F support"
1425         depends on ISA && SCSI && ISA_DMA_API
1426         ---help---
1427           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1428           The source at <file:drivers/scsi/u14-34f.c> contains some
1429           information about this hardware.  If the driver doesn't work out of
1430           the box, you may have to change some settings in
1431           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1432           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1433           another driver for the same hardware: "UltraStor SCSI support",
1434           below.  You should say Y to both only if you want 24F support as
1435           well.
1436
1437           To compile this driver as a module, choose M here: the
1438           module will be called u14-34f.
1439
1440 config SCSI_U14_34F_TAGGED_QUEUE
1441         bool "enable tagged command queueing"
1442         depends on SCSI_U14_34F
1443         help
1444           This is a feature of SCSI-2 which improves performance: the host
1445           adapter can send several SCSI commands to a device's queue even if
1446           previous commands haven't finished yet.
1447           This is equivalent to the "u14-34f=tc:y" boot option.
1448
1449 config SCSI_U14_34F_LINKED_COMMANDS
1450         bool "enable elevator sorting"
1451         depends on SCSI_U14_34F
1452         help
1453           This option enables elevator sorting for all probed SCSI disks and
1454           CD-ROMs. It definitely reduces the average seek distance when doing
1455           random seeks, but this does not necessarily result in a noticeable
1456           performance improvement: your mileage may vary...
1457           This is equivalent to the "u14-34f=lc:y" boot option.
1458
1459 config SCSI_U14_34F_MAX_TAGS
1460         int "maximum number of queued commands"
1461         depends on SCSI_U14_34F
1462         default "8"
1463         help
1464           This specifies how many SCSI commands can be maximally queued for
1465           each probed SCSI device. You should reduce the default value of 8
1466           only if you have disks with buggy or limited tagged command support.
1467           Minimum is 2 and maximum is 14. This value is also the window size
1468           used by the elevator sorting option above. The effective value used
1469           by the driver for each probed SCSI device is reported at boot time.
1470           This is equivalent to the "u14-34f=mq:8" boot option.
1471
1472 config SCSI_ULTRASTOR
1473         tristate "UltraStor SCSI support"
1474         depends on X86 && ISA && SCSI
1475         ---help---
1476           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1477           adapter family.  This driver is explained in section 3.12 of the
1478           SCSI-HOWTO, available from
1479           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1480           of the box, you may have to change some settings in
1481           <file:drivers/scsi/ultrastor.h>.
1482
1483           Note that there is also another driver for the same hardware:
1484           "UltraStor 14F/34F support", above.
1485
1486           To compile this driver as a module, choose M here: the
1487           module will be called ultrastor.
1488
1489 config SCSI_NSP32
1490         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1491         depends on PCI && SCSI && !64BIT
1492         help
1493           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1494           SCSI host adapter. Please read the SCSI-HOWTO, available from
1495           <http://www.tldp.org/docs.html#howto>.
1496
1497           To compile this driver as a module, choose M here: the
1498           module will be called nsp32.
1499
1500 config SCSI_DEBUG
1501         tristate "SCSI debugging host simulator"
1502         depends on SCSI
1503         help
1504           This is a host adapter simulator that can simulate multiple hosts
1505           each with multiple dummy SCSI devices (disks). It defaults to one
1506           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1507           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1508           dummy disks are simulated, they share the same kernel RAM for 
1509           their storage. See <http://www.torque.net/sg/sdebug.html> for more
1510           information. This driver is primarily of use to those testing the
1511           SCSI and block subsystems. If unsure, say N.
1512
1513 config SCSI_MESH
1514         tristate "MESH (Power Mac internal SCSI) support"
1515         depends on PPC32 && PPC_PMAC && SCSI
1516         help
1517           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1518           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1519           other Power Macintoshes do). Say Y to include support for this SCSI
1520           adaptor.
1521
1522           To compile this driver as a module, choose M here: the
1523           module will be called mesh.
1524
1525 config SCSI_MESH_SYNC_RATE
1526         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1527         depends on SCSI_MESH
1528         default "5"
1529         help
1530           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1531           drives a bus which is entirely internal to the machine (such as the
1532           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1533           operation at up to 10 MB/s. On machines where the SCSI bus
1534           controlled by the MESH can have external devices connected, it is
1535           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1536           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1537           to disable synchronous operation.
1538
1539 config SCSI_MESH_RESET_DELAY_MS
1540         int "initial bus reset delay (ms) (0 = no reset)"
1541         depends on SCSI_MESH
1542         default "4000"
1543
1544 config SCSI_MAC53C94
1545         tristate "53C94 (Power Mac external SCSI) support"
1546         depends on PPC32 && PPC_PMAC && SCSI
1547         help
1548           On Power Macintoshes (and clones) with two SCSI buses, the external
1549           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1550           machines which only have one SCSI bus, such as the 7200, also use
1551           the 53C94. Say Y to include support for the 53C94.
1552
1553           To compile this driver as a module, choose M here: the
1554           module will be called mac53c94.
1555
1556 source "drivers/scsi/arm/Kconfig"
1557
1558 config JAZZ_ESP
1559         bool "MIPS JAZZ FAS216 SCSI support"
1560         depends on MACH_JAZZ && SCSI
1561         select SCSI_SPI_ATTRS
1562         help
1563           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1564           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1565           systems.
1566
1567 config A3000_SCSI
1568         tristate "A3000 WD33C93A support"
1569         depends on AMIGA && SCSI
1570         help
1571           If you have an Amiga 3000 and have SCSI devices connected to the
1572           built-in SCSI controller, say Y. Otherwise, say N.
1573
1574           To compile this driver as a module, choose M here: the
1575           module will be called a3000.
1576
1577 config A2091_SCSI
1578         tristate "A2091/A590 WD33C93A support"
1579         depends on ZORRO && SCSI
1580         help
1581           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1582           say N.
1583
1584           To compile this driver as a module, choose M here: the
1585           module will be called a2091.
1586
1587 config GVP11_SCSI
1588         tristate "GVP Series II WD33C93A support"
1589         depends on ZORRO && SCSI
1590         ---help---
1591           If you have a Great Valley Products Series II SCSI controller,
1592           answer Y. Also say Y if you have a later model of GVP SCSI
1593           controller (such as the GVP A4008 or a Combo board). Otherwise,
1594           answer N. This driver does NOT work for the T-Rex series of
1595           accelerators from TekMagic and GVP-M.
1596
1597           To compile this driver as a module, choose M here: the
1598           module will be called gvp11.
1599
1600 config SCSI_A4000T
1601         tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
1602         depends on AMIGA && SCSI && EXPERIMENTAL
1603         select SCSI_SPI_ATTRS
1604         help
1605           If you have an Amiga 4000T and have SCSI devices connected to the
1606           built-in SCSI controller, say Y. Otherwise, say N.
1607
1608           To compile this driver as a module, choose M here: the
1609           module will be called a4000t.
1610
1611 config SCSI_ZORRO7XX
1612         tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
1613         depends on ZORRO && SCSI && EXPERIMENTAL
1614         select SCSI_SPI_ATTRS
1615         help
1616           Support for various NCR53c710-based SCSI controllers on Zorro
1617           expansion boards for the Amiga.
1618           This includes:
1619             - the Amiga 4091 Zorro III SCSI-2 controller,
1620             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1621               (info at
1622               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1623             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1624               accelerator card for the Amiga 1200,
1625             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1626
1627 config ATARI_SCSI
1628         tristate "Atari native SCSI support"
1629         depends on ATARI && SCSI
1630         select SCSI_SPI_ATTRS
1631         ---help---
1632           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1633           Falcon, ...) say Y to get it supported. Of course also, if you have
1634           a compatible SCSI controller (e.g. for Medusa).
1635
1636           To compile this driver as a module, choose M here: the
1637           module will be called atari_scsi.
1638
1639           This driver supports both styles of NCR integration into the
1640           system: the TT style (separate DMA), and the Falcon style (via
1641           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1642           in the Hades (without DMA).
1643
1644 config ATARI_SCSI_TOSHIBA_DELAY
1645         bool "Long delays for Toshiba CD-ROMs"
1646         depends on ATARI_SCSI
1647         help
1648           This option increases the delay after a SCSI arbitration to
1649           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1650           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1651           would impact performance a bit, so say N.
1652
1653 config ATARI_SCSI_RESET_BOOT
1654         bool "Reset SCSI-devices at boottime"
1655         depends on ATARI_SCSI
1656         help
1657           Reset the devices on your Atari whenever it boots.  This makes the
1658           boot process fractionally longer but may assist recovery from errors
1659           that leave the devices with SCSI operations partway completed.
1660
1661 config TT_DMA_EMUL
1662         bool "Hades SCSI DMA emulator"
1663         depends on ATARI_SCSI && HADES
1664         help
1665           This option enables code which emulates the TT SCSI DMA chip on the
1666           Hades. This increases the SCSI transfer rates at least ten times
1667           compared to PIO transfers.
1668
1669 config MAC_SCSI
1670         bool "Macintosh NCR5380 SCSI"
1671         depends on MAC && SCSI=y
1672         select SCSI_SPI_ATTRS
1673         help
1674           This is the NCR 5380 SCSI controller included on most of the 68030
1675           based Macintoshes.  If you have one of these say Y and read the
1676           SCSI-HOWTO, available from
1677           <http://www.tldp.org/docs.html#howto>.
1678
1679 config SCSI_MAC_ESP
1680         tristate "Macintosh NCR53c9[46] SCSI"
1681         depends on MAC && SCSI
1682         select SCSI_SPI_ATTRS
1683         help
1684           This is the NCR 53c9x SCSI controller found on most of the 68040
1685           based Macintoshes.
1686
1687           To compile this driver as a module, choose M here: the module
1688           will be called mac_esp.
1689
1690 config MVME147_SCSI
1691         bool "WD33C93 SCSI driver for MVME147"
1692         depends on MVME147 && SCSI=y
1693         select SCSI_SPI_ATTRS
1694         help
1695           Support for the on-board SCSI controller on the Motorola MVME147
1696           single-board computer.
1697
1698 config MVME16x_SCSI
1699         tristate "NCR53C710 SCSI driver for MVME16x"
1700         depends on MVME16x && SCSI
1701         select SCSI_SPI_ATTRS
1702         help
1703           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1704           SCSI controller chip.  Almost everyone using one of these boards
1705           will want to say Y to this question.
1706
1707 config BVME6000_SCSI
1708         tristate "NCR53C710 SCSI driver for BVME6000"
1709         depends on BVME6000 && SCSI
1710         select SCSI_SPI_ATTRS
1711         help
1712           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1713           SCSI controller chip.  Almost everyone using one of these boards
1714           will want to say Y to this question.
1715
1716 config SUN3_SCSI
1717         tristate "Sun3 NCR5380 SCSI"
1718         depends on SUN3 && SCSI
1719         select SCSI_SPI_ATTRS
1720         help
1721           This option will enable support for the OBIO (onboard io) NCR5380
1722           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1723           "Sun3" type VME scsi controllers also based on the NCR5380.
1724           General Linux information on the Sun 3 series (now discontinued)
1725           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1726
1727 config SUN3X_ESP
1728         bool "Sun3x ESP SCSI"
1729         depends on SUN3X && SCSI=y
1730         select SCSI_SPI_ATTRS
1731         help
1732           The ESP was an on-board SCSI controller used on Sun 3/80
1733           machines.  Say Y here to compile in support for it.
1734
1735 config SCSI_SUNESP
1736         tristate "Sparc ESP Scsi Driver"
1737         depends on SBUS && SCSI
1738         select SCSI_SPI_ATTRS
1739         help
1740           This is the driver for the Sun ESP SCSI host adapter. The ESP
1741           chipset is present in most SPARC SBUS-based computers.
1742
1743           To compile this driver as a module, choose M here: the
1744           module will be called esp.
1745
1746 config ZFCP
1747         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1748         depends on S390 && QDIO && SCSI
1749         select SCSI_FC_ATTRS
1750         help
1751           If you want to access SCSI devices attached to your IBM eServer
1752           zSeries by means of Fibre Channel interfaces say Y.
1753           For details please refer to the documentation provided by IBM at
1754           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1755
1756           This driver is also available as a module. This module will be
1757           called zfcp. If you want to compile it as a module, say M here
1758           and read <file:Documentation/kbuild/modules.txt>.
1759
1760 config SCSI_SRP
1761         tristate "SCSI RDMA Protocol helper library"
1762         depends on SCSI && PCI
1763         select SCSI_TGT
1764         help
1765           If you wish to use SRP target drivers, say Y.
1766
1767           To compile this driver as a module, choose M here: the
1768           module will be called libsrp.
1769
1770 endif # SCSI_LOWLEVEL
1771
1772 source "drivers/scsi/pcmcia/Kconfig"
1773
1774 endmenu