Merge branch 'master' of git://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux...
[linux-2.6] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config RAID_ATTRS
4         tristate "RAID Transport Class"
5         default n
6         depends on BLOCK
7         ---help---
8           Provides RAID
9
10 config SCSI
11         tristate "SCSI device support"
12         depends on BLOCK
13         select SCSI_DMA if HAS_DMA
14         ---help---
15           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
16           any other SCSI device under Linux, say Y and make sure that you know
17           the name of your SCSI host adapter (the card inside your computer
18           that "speaks" the SCSI protocol, also called SCSI controller),
19           because you will be asked for it.
20
21           You also need to say Y here if you have a device which speaks
22           the SCSI protocol.  Examples of this include the parallel port
23           version of the IOMEGA ZIP drive, USB storage devices, Fibre
24           Channel, FireWire storage and the IDE-SCSI emulation driver.
25
26           To compile this driver as a module, choose M here and read
27           <file:Documentation/scsi/scsi.txt>.
28           The module will be called scsi_mod.
29
30           However, do not compile this as a module if your root file system
31           (the one containing the directory /) is located on a SCSI device.
32
33 config SCSI_DMA
34         bool
35         default n
36
37 config SCSI_TGT
38         tristate "SCSI target support"
39         depends on SCSI && EXPERIMENTAL
40         ---help---
41           If you want to use SCSI target mode drivers enable this option.
42           If you choose M, the module will be called scsi_tgt.
43
44 config SCSI_NETLINK
45         bool
46         default n
47         select NET
48
49 config SCSI_PROC_FS
50         bool "legacy /proc/scsi/ support"
51         depends on SCSI && PROC_FS
52         default y
53         ---help---
54           This option enables support for the various files in
55           /proc/scsi.  In Linux 2.6 this has been superseded by
56           files in sysfs but many legacy applications rely on this.
57
58           If unsure say Y.
59
60 comment "SCSI support type (disk, tape, CD-ROM)"
61         depends on SCSI
62
63 config BLK_DEV_SD
64         tristate "SCSI disk support"
65         depends on SCSI
66         select CRC_T10DIF if BLK_DEV_INTEGRITY
67         ---help---
68           If you want to use SCSI hard disks, Fibre Channel disks,
69           Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
70           USB storage or the SCSI or parallel port version of
71           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
72           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
73           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
74           CD-ROMs.
75
76           To compile this driver as a module, choose M here and read
77           <file:Documentation/scsi/scsi.txt>.
78           The module will be called sd_mod.
79
80           Do not compile this driver as a module if your root file system
81           (the one containing the directory /) is located on a SCSI disk.
82           In this case, do not compile the driver for your SCSI host adapter
83           (below) as a module either.
84
85 config CHR_DEV_ST
86         tristate "SCSI tape support"
87         depends on SCSI
88         ---help---
89           If you want to use a SCSI tape drive under Linux, say Y and read the
90           SCSI-HOWTO, available from
91           <http://www.tldp.org/docs.html#howto>, and
92           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
93           for SCSI CD-ROMs.
94
95           To compile this driver as a module, choose M here and read
96           <file:Documentation/scsi/scsi.txt>. The module will be called st.
97
98 config CHR_DEV_OSST
99         tristate "SCSI OnStream SC-x0 tape support"
100         depends on SCSI
101         ---help---
102           The OnStream SC-x0 SCSI tape drives cannot be driven by the
103           standard st driver, but instead need this special osst driver and
104           use the  /dev/osstX char device nodes (major 206).  Via usb-storage
105           and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
106           as well.  Note that there is also a second generation of OnStream
107           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
108           tapes (QIC-157) and can be driven by the standard driver st.
109           For more information, you may have a look at the SCSI-HOWTO
110           <http://www.tldp.org/docs.html#howto>  and
111           <file:Documentation/scsi/osst.txt>  in the kernel source.
112           More info on the OnStream driver may be found on
113           <http://linux1.onstream.nl/test/>
114           Please also have a look at the standard st docu, as most of it
115           applies to osst as well.
116
117           To compile this driver as a module, choose M here and read
118           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
119
120 config BLK_DEV_SR
121         tristate "SCSI CDROM support"
122         depends on SCSI
123         ---help---
124           If you want to use a SCSI or FireWire CD-ROM under Linux,
125           say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
126           <http://www.tldp.org/docs.html#howto>. Also make sure to say
127           Y or M to "ISO 9660 CD-ROM file system support" later.
128
129           To compile this driver as a module, choose M here and read
130           <file:Documentation/scsi/scsi.txt>.
131           The module will be called sr_mod.
132
133 config BLK_DEV_SR_VENDOR
134         bool "Enable vendor-specific extensions (for SCSI CDROM)"
135         depends on BLK_DEV_SR
136         help
137           This enables the usage of vendor specific SCSI commands. This is
138           required to support multisession CDs with old NEC/TOSHIBA cdrom
139           drives (and HP Writers). If you have such a drive and get the first
140           session only, try saying Y here; everybody else says N.
141
142 config CHR_DEV_SG
143         tristate "SCSI generic support"
144         depends on SCSI
145         ---help---
146           If you want to use SCSI scanners, synthesizers or CD-writers or just
147           about anything having "SCSI" in its name other than hard disks,
148           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
149           directly, so you need some additional software which knows how to
150           talk to these devices using the SCSI protocol:
151
152           For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
153           writer software look at Cdrtools
154           (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
155           and for burning a "disk at once": CDRDAO
156           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
157           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
158           For other devices, it's possible that you'll have to write the
159           driver software yourself. Please read the file
160           <file:Documentation/scsi/scsi-generic.txt> for more information.
161
162           To compile this driver as a module, choose M here and read
163           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
164
165           If unsure, say N.
166
167 config CHR_DEV_SCH
168         tristate "SCSI media changer support"
169         depends on SCSI
170         ---help---
171           This is a driver for SCSI media changers.  Most common devices are
172           tape libraries and MOD/CDROM jukeboxes.  *Real* jukeboxes, you
173           don't need this for those tiny 6-slot cdrom changers.  Media
174           changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
175           If you have such hardware and want to use it with linux, say Y
176           here.  Check <file:Documentation/scsi/scsi-changer.txt> for details.
177         
178           If you want to compile this as a module ( = code which can be
179           inserted in and removed from the running kernel whenever you want),
180           say M here and read <file:Documentation/kbuild/modules.txt> and
181           <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
182           If unsure, say N.
183
184 config SCSI_ENCLOSURE
185         tristate "SCSI Enclosure Support"
186         depends on SCSI && ENCLOSURE_SERVICES
187         help
188           Enclosures are devices sitting on or in SCSI backplanes that
189           manage devices.  If you have a disk cage, the chances are that
190           it has an enclosure device.  Selecting this option will just allow
191           certain enclosure conditions to be reported and is not required.
192
193 comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
194         depends on SCSI
195
196 config SCSI_MULTI_LUN
197         bool "Probe all LUNs on each SCSI device"
198         depends on SCSI
199         help
200           If you have a SCSI device that supports more than one LUN (Logical
201           Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
202           can say Y here to force the SCSI driver to probe for multiple LUNs.
203           A SCSI device with multiple LUNs acts logically like multiple SCSI
204           devices. The vast majority of SCSI devices have only one LUN, and
205           so most people can say N here. The max_luns boot/module parameter 
206           allows to override this setting.
207
208 config SCSI_CONSTANTS
209         bool "Verbose SCSI error reporting (kernel size +=12K)"
210         depends on SCSI
211         help
212           The error messages regarding your SCSI hardware will be easier to
213           understand if you say Y here; it will enlarge your kernel by about
214           12 KB. If in doubt, say Y.
215
216 config SCSI_LOGGING
217         bool "SCSI logging facility"
218         depends on SCSI
219         ---help---
220           This turns on a logging facility that can be used to debug a number
221           of SCSI related problems.
222
223           If you say Y here, no logging output will appear by default, but you
224           can enable logging by saying Y to "/proc file system support" and
225           "Sysctl support" below and executing the command
226
227           echo "scsi log token [level]" > /proc/scsi/scsi
228
229           at boot time after the /proc file system has been mounted.
230
231           There are a number of things that can be used for 'token' (you can
232           find them in the source: <file:drivers/scsi/scsi.c>), and this
233           allows you to select the types of information you want, and the
234           level allows you to select the level of verbosity.
235
236           If you say N here, it may be harder to track down some types of SCSI
237           problems. If you say Y here your kernel will be somewhat larger, but
238           there should be no noticeable performance impact as long as you have
239           logging turned off.
240
241 config SCSI_SCAN_ASYNC
242         bool "Asynchronous SCSI scanning"
243         depends on SCSI
244         help
245           The SCSI subsystem can probe for devices while the rest of the
246           system continues booting, and even probe devices on different
247           busses in parallel, leading to a significant speed-up.
248
249           If you have built SCSI as modules, enabling this option can
250           be a problem as the devices may not have been found by the
251           time your system expects them to have been.  You can load the
252           scsi_wait_scan module to ensure that all scans have completed.
253           If you build your SCSI drivers into the kernel, then everything
254           will work fine if you say Y here.
255
256           You can override this choice by specifying "scsi_mod.scan=sync"
257           or async on the kernel's command line.
258
259 config SCSI_WAIT_SCAN
260         tristate
261         default m
262         depends on SCSI
263         depends on MODULES
264
265 menu "SCSI Transports"
266         depends on SCSI
267
268 config SCSI_SPI_ATTRS
269         tristate "Parallel SCSI (SPI) Transport Attributes"
270         depends on SCSI
271         help
272           If you wish to export transport-specific information about
273           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
274
275 config SCSI_FC_ATTRS
276         tristate "FiberChannel Transport Attributes"
277         depends on SCSI
278         select SCSI_NETLINK
279         help
280           If you wish to export transport-specific information about
281           each attached FiberChannel device to sysfs, say Y.
282           Otherwise, say N.
283
284 config SCSI_FC_TGT_ATTRS
285         bool "SCSI target support for FiberChannel Transport Attributes"
286         depends on SCSI_FC_ATTRS
287         depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
288         help
289                 If you want to use SCSI target mode drivers enable this option.
290
291 config SCSI_ISCSI_ATTRS
292         tristate "iSCSI Transport Attributes"
293         depends on SCSI && NET
294         help
295           If you wish to export transport-specific information about
296           each attached iSCSI device to sysfs, say Y.
297           Otherwise, say N.
298
299 config SCSI_SAS_ATTRS
300         tristate "SAS Transport Attributes"
301         depends on SCSI && BLK_DEV_BSG
302         help
303           If you wish to export transport-specific information about
304           each attached SAS device to sysfs, say Y.
305
306 source "drivers/scsi/libsas/Kconfig"
307
308 config SCSI_SRP_ATTRS
309         tristate "SRP Transport Attributes"
310         depends on SCSI
311         help
312           If you wish to export transport-specific information about
313           each attached SRP device to sysfs, say Y.
314
315 config SCSI_SRP_TGT_ATTRS
316         bool "SCSI target support for SRP Transport Attributes"
317         depends on SCSI_SRP_ATTRS
318         depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
319         help
320                 If you want to use SCSI target mode drivers enable this option.
321
322 endmenu
323
324 menuconfig SCSI_LOWLEVEL
325         bool "SCSI low-level drivers"
326         depends on SCSI!=n
327         default y
328
329 if SCSI_LOWLEVEL && SCSI
330
331 config ISCSI_TCP
332         tristate "iSCSI Initiator over TCP/IP"
333         depends on SCSI && INET
334         select CRYPTO
335         select CRYPTO_MD5
336         select CRYPTO_CRC32C
337         select SCSI_ISCSI_ATTRS
338         help
339          The iSCSI Driver provides a host with the ability to access storage
340          through an IP network. The driver uses the iSCSI protocol to transport
341          SCSI requests and responses over a TCP/IP network between the host
342          (the "initiator") and "targets".  Architecturally, the iSCSI driver
343          combines with the host's TCP/IP stack, network drivers, and Network
344          Interface Card (NIC) to provide the same functions as a SCSI or a
345          Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
346
347          To compile this driver as a module, choose M here: the
348          module will be called iscsi_tcp.
349
350          The userspace component needed to initialize the driver, documentation,
351          and sample configuration files can be found here:
352
353          http://open-iscsi.org
354
355 source "drivers/scsi/cxgb3i/Kconfig"
356
357 config SGIWD93_SCSI
358         tristate "SGI WD93C93 SCSI Driver"
359         depends on SGI_HAS_WD93 && SCSI
360         help
361           If you have a Western Digital WD93 SCSI controller on
362           an SGI MIPS system, say Y.  Otherwise, say N.
363
364 config BLK_DEV_3W_XXXX_RAID
365         tristate "3ware 5/6/7/8xxx ATA-RAID support"
366         depends on PCI && SCSI
367         help
368           3ware is the only hardware ATA-Raid product in Linux to date.
369           This card is 2,4, or 8 channel master mode support only.
370           SCSI support required!!!
371
372           <http://www.3ware.com/>
373
374           Please read the comments at the top of
375           <file:drivers/scsi/3w-xxxx.c>.
376
377 config SCSI_3W_9XXX
378         tristate "3ware 9xxx SATA-RAID support"
379         depends on PCI && SCSI
380         help
381           This driver supports the 9000 series 3ware SATA-RAID cards.
382
383           <http://www.amcc.com>
384
385           Please read the comments at the top of
386           <file:drivers/scsi/3w-9xxx.c>.
387
388 config SCSI_7000FASST
389         tristate "7000FASST SCSI support"
390         depends on ISA && SCSI && ISA_DMA_API
391         select CHECK_SIGNATURE
392         help
393           This driver supports the Western Digital 7000 SCSI host adapter
394           family.  Some information is in the source:
395           <file:drivers/scsi/wd7000.c>.
396
397           To compile this driver as a module, choose M here: the
398           module will be called wd7000.
399
400 config SCSI_ACARD
401         tristate "ACARD SCSI support"
402         depends on PCI && SCSI
403         help
404           This driver supports the ACARD SCSI host adapter.
405           Support Chip <ATP870 ATP876 ATP880 ATP885>
406           To compile this driver as a module, choose M here: the
407           module will be called atp870u.
408
409 config SCSI_AHA152X
410         tristate "Adaptec AHA152X/2825 support"
411         depends on ISA && SCSI && !64BIT
412         select SCSI_SPI_ATTRS
413         select CHECK_SIGNATURE
414         ---help---
415           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
416           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
417           must be manually specified in this case.
418
419           It is explained in section 3.3 of the SCSI-HOWTO, available from
420           <http://www.tldp.org/docs.html#howto>. You might also want to
421           read the file <file:Documentation/scsi/aha152x.txt>.
422
423           To compile this driver as a module, choose M here: the
424           module will be called aha152x.
425
426 config SCSI_AHA1542
427         tristate "Adaptec AHA1542 support"
428         depends on ISA && SCSI && ISA_DMA_API
429         ---help---
430           This is support for a SCSI host adapter.  It is explained in section
431           3.4 of the SCSI-HOWTO, available from
432           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
433           purchased by Adaptec, and some former Trantor products are being
434           sold under the Adaptec name.  If it doesn't work out of the box, you
435           may have to change some settings in <file:drivers/scsi/aha1542.h>.
436
437           To compile this driver as a module, choose M here: the
438           module will be called aha1542.
439
440 config SCSI_AHA1740
441         tristate "Adaptec AHA1740 support"
442         depends on EISA && SCSI
443         ---help---
444           This is support for a SCSI host adapter.  It is explained in section
445           3.5 of the SCSI-HOWTO, available from
446           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
447           of the box, you may have to change some settings in
448           <file:drivers/scsi/aha1740.h>.
449
450           To compile this driver as a module, choose M here: the
451           module will be called aha1740.
452
453 config SCSI_AACRAID
454         tristate "Adaptec AACRAID support"
455         depends on SCSI && PCI
456         help
457           This driver supports a variety of Dell, HP, Adaptec, IBM and
458           ICP storage products. For a list of supported products, refer
459           to <file:Documentation/scsi/aacraid.txt>.
460
461           To compile this driver as a module, choose M here: the module
462           will be called aacraid.
463
464
465 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
466
467 config SCSI_AIC7XXX_OLD
468         tristate "Adaptec AIC7xxx support (old driver)"
469         depends on (ISA || EISA || PCI ) && SCSI
470         help
471           WARNING This driver is an older aic7xxx driver and is no longer
472           under active development.  Adaptec, Inc. is writing a new driver to
473           take the place of this one, and it is recommended that whenever
474           possible, people should use the new Adaptec written driver instead
475           of this one.  This driver will eventually be phased out entirely.
476
477           This is support for the various aic7xxx based Adaptec SCSI
478           controllers. These include the 274x EISA cards; 284x VLB cards;
479           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
480           motherboard based SCSI controllers from Adaptec. It does not support
481           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
482           support them. It does not support the 2920 cards from Adaptec that
483           use the Future Domain SCSI controller chip. For those cards, you
484           need the "Future Domain 16xx SCSI support" driver.
485
486           In general, if the controller is based on an Adaptec SCSI controller
487           chip from the aic777x series or the aic78xx series, this driver
488           should work. The only exception is the 7810 which is specifically
489           not supported (that's the RAID controller chip on the AAA-13x
490           cards).
491
492           Note that the AHA2920 SCSI host adapter is *not* supported by this
493           driver; choose "Future Domain 16xx SCSI support" instead if you have
494           one of those.
495
496           Information on the configuration options for this controller can be
497           found by checking the help file for each of the available
498           configuration options. You should read
499           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
500           contacting the maintainer with any questions.  The SCSI-HOWTO,
501           available from <http://www.tldp.org/docs.html#howto>, can also
502           be of great help.
503
504           To compile this driver as a module, choose M here: the
505           module will be called aic7xxx_old.
506
507 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
508 source "drivers/scsi/aic94xx/Kconfig"
509
510 config SCSI_DPT_I2O
511         tristate "Adaptec I2O RAID support "
512         depends on SCSI && PCI && VIRT_TO_BUS
513         help
514           This driver supports all of Adaptec's I2O based RAID controllers as 
515           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
516           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
517
518           To compile this driver as a module, choose M here: the
519           module will be called dpt_i2o.
520
521 config SCSI_ADVANSYS
522         tristate "AdvanSys SCSI support"
523         depends on SCSI && VIRT_TO_BUS
524         depends on ISA || EISA || PCI
525         help
526           This is a driver for all SCSI host adapters manufactured by
527           AdvanSys. It is documented in the kernel source in
528           <file:drivers/scsi/advansys.c>.
529
530           To compile this driver as a module, choose M here: the
531           module will be called advansys.
532
533 config SCSI_IN2000
534         tristate "Always IN2000 SCSI support"
535         depends on ISA && SCSI
536         help
537           This is support for an ISA bus SCSI host adapter.  You'll find more
538           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
539           out of the box, you may have to change the jumpers for IRQ or
540           address selection.
541
542           To compile this driver as a module, choose M here: the
543           module will be called in2000.
544
545 config SCSI_ARCMSR
546         tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
547         depends on PCI && SCSI
548         help
549           This driver supports all of ARECA's SATA/SAS RAID controller cards.
550           This is an ARECA-maintained driver by Erich Chen.
551           If you have any problems, please mail to: <erich@areca.com.tw>.
552           Areca supports Linux RAID config tools.
553           Please link <http://www.areca.com.tw>
554
555           To compile this driver as a module, choose M here: the
556           module will be called arcmsr (modprobe arcmsr).
557
558 config SCSI_ARCMSR_AER
559         bool "Enable PCI Error Recovery Capability in Areca Driver(ARCMSR)"
560         depends on SCSI_ARCMSR && PCIEAER
561         default n
562         help
563           The advanced error reporting(AER) capability is "NOT" provided by
564           ARC1200/1201/1202 SATA RAID controllers cards.
565           If your card is one of ARC1200/1201/1202, please use the default setting, n.
566           If your card is other models, you could pick it
567           on condition that the kernel version is greater than 2.6.19.
568           This function is maintained driver by Nick Cheng. If you have any
569           problems or suggestion, you are welcome to contact with <nick.cheng@areca.com.tw>.
570           To enable this function, choose Y here.
571
572 source "drivers/scsi/megaraid/Kconfig.megaraid"
573
574 config SCSI_HPTIOP
575         tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
576         depends on SCSI && PCI
577         help
578           This option enables support for HighPoint RocketRAID 3xxx/4xxx
579           controllers.
580
581           To compile this driver as a module, choose M here; the module
582           will be called hptiop. If unsure, say N.
583
584 config SCSI_BUSLOGIC
585         tristate "BusLogic SCSI support"
586         depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
587         ---help---
588           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
589           Adapters. Consult the SCSI-HOWTO, available from
590           <http://www.tldp.org/docs.html#howto>, and the files
591           <file:Documentation/scsi/BusLogic.txt> and
592           <file:Documentation/scsi/FlashPoint.txt> for more information.
593           Note that support for FlashPoint is only available for 32-bit
594           x86 configurations.
595
596           To compile this driver as a module, choose M here: the
597           module will be called BusLogic.
598
599 config SCSI_FLASHPOINT
600         bool "FlashPoint support"
601         depends on SCSI_BUSLOGIC && PCI && X86_32
602         help
603           This option allows you to add FlashPoint support to the
604           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
605           substantial, so users of MultiMaster Host Adapters may not
606           wish to include it.
607
608 config LIBFC
609         tristate "LibFC module"
610         select SCSI_FC_ATTRS
611         ---help---
612           Fibre Channel library module
613
614 config FCOE
615         tristate "FCoE module"
616         depends on PCI
617         select LIBFC
618         ---help---
619           Fibre Channel over Ethernet module
620
621 config SCSI_DMX3191D
622         tristate "DMX3191D SCSI support"
623         depends on PCI && SCSI
624         select SCSI_SPI_ATTRS
625         help
626           This is support for Domex DMX3191D SCSI Host Adapters.
627
628           To compile this driver as a module, choose M here: the
629           module will be called dmx3191d.
630
631 config SCSI_DTC3280
632         tristate "DTC3180/3280 SCSI support"
633         depends on ISA && SCSI
634         select SCSI_SPI_ATTRS
635         select CHECK_SIGNATURE
636         help
637           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
638           the SCSI-HOWTO, available from
639           <http://www.tldp.org/docs.html#howto>, and the file
640           <file:Documentation/scsi/dtc3x80.txt>.
641
642           To compile this driver as a module, choose M here: the
643           module will be called dtc.
644
645 config SCSI_EATA
646         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
647         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
648         ---help---
649           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
650           ISA and all EISA I/O addresses are probed looking for the "EATA"
651           signature. The addresses of all the PCI SCSI controllers reported
652           by the PCI subsystem are probed as well.
653
654           You want to read the start of <file:drivers/scsi/eata.c> and the
655           SCSI-HOWTO, available from
656           <http://www.tldp.org/docs.html#howto>.
657
658           To compile this driver as a module, choose M here: the
659           module will be called eata.
660
661 config SCSI_EATA_TAGGED_QUEUE
662         bool "enable tagged command queueing"
663         depends on SCSI_EATA
664         help
665           This is a feature of SCSI-2 which improves performance: the host
666           adapter can send several SCSI commands to a device's queue even if
667           previous commands haven't finished yet.
668           This is equivalent to the "eata=tc:y" boot option.
669
670 config SCSI_EATA_LINKED_COMMANDS
671         bool "enable elevator sorting"
672         depends on SCSI_EATA
673         help
674           This option enables elevator sorting for all probed SCSI disks and
675           CD-ROMs. It definitely reduces the average seek distance when doing
676           random seeks, but this does not necessarily result in a noticeable
677           performance improvement: your mileage may vary...
678           This is equivalent to the "eata=lc:y" boot option.
679
680 config SCSI_EATA_MAX_TAGS
681         int "maximum number of queued commands"
682         depends on SCSI_EATA
683         default "16"
684         help
685           This specifies how many SCSI commands can be maximally queued for
686           each probed SCSI device. You should reduce the default value of 16
687           only if you have disks with buggy or limited tagged command support.
688           Minimum is 2 and maximum is 62. This value is also the window size
689           used by the elevator sorting option above. The effective value used
690           by the driver for each probed SCSI device is reported at boot time.
691           This is equivalent to the "eata=mq:8" boot option.
692
693 config SCSI_EATA_PIO
694         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
695         depends on (ISA || EISA || PCI) && SCSI && BROKEN
696         ---help---
697           This driver supports all EATA-PIO protocol compliant SCSI Host
698           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
699           host adapters could also use this driver but are discouraged from
700           doing so, since this driver only supports hard disks and lacks
701           numerous features.  You might want to have a look at the SCSI-HOWTO,
702           available from <http://www.tldp.org/docs.html#howto>.
703
704           To compile this driver as a module, choose M here: the
705           module will be called eata_pio.
706
707 config SCSI_FUTURE_DOMAIN
708         tristate "Future Domain 16xx SCSI/AHA-2920A support"
709         depends on (ISA || PCI) && SCSI
710         select CHECK_SIGNATURE
711         ---help---
712           This is support for Future Domain's 16-bit SCSI host adapters
713           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
714           other adapters based on the Future Domain chipsets (Quantum
715           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
716           It is explained in section 3.7 of the SCSI-HOWTO, available from
717           <http://www.tldp.org/docs.html#howto>.
718
719           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
720           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
721           controller support"). This Future Domain driver works with the older
722           Adaptec AHA-2920A boards with a Future Domain chip on them.
723
724           To compile this driver as a module, choose M here: the
725           module will be called fdomain.
726
727 config SCSI_FD_MCS
728         tristate "Future Domain MCS-600/700 SCSI support"
729         depends on MCA_LEGACY && SCSI
730         ---help---
731           This is support for Future Domain MCS 600/700 MCA SCSI adapters.
732           Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
733           is identical to the MCS 700 and hence also supported by this driver.
734           This driver also supports the Reply SB16/SCSI card (the SCSI part).
735           It supports multiple adapters in the same system.
736
737           To compile this driver as a module, choose M here: the
738           module will be called fd_mcs.
739
740 config SCSI_GDTH
741         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
742         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
743         ---help---
744           Formerly called GDT SCSI Disk Array Controller Support.
745
746           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
747           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
748           in the kernel source in <file:drivers/scsi/gdth.c> and
749           <file:drivers/scsi/gdth.h>.
750
751           To compile this driver as a module, choose M here: the
752           module will be called gdth.
753
754 config SCSI_GENERIC_NCR5380
755         tristate "Generic NCR5380/53c400 SCSI PIO support"
756         depends on ISA && SCSI
757         select SCSI_SPI_ATTRS
758         ---help---
759           This is a driver for the old NCR 53c80 series of SCSI controllers
760           on boards using PIO. Most boards such as the Trantor T130 fit this
761           category, along with a large number of ISA 8bit controllers shipped
762           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
763           you should select the specific driver for that card rather than
764           generic 5380 support.
765
766           It is explained in section 3.8 of the SCSI-HOWTO, available from
767           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
768           of the box, you may have to change some settings in
769           <file:drivers/scsi/g_NCR5380.h>.
770
771           To compile this driver as a module, choose M here: the
772           module will be called g_NCR5380.
773
774 config SCSI_GENERIC_NCR5380_MMIO
775         tristate "Generic NCR5380/53c400 SCSI MMIO support"
776         depends on ISA && SCSI
777         select SCSI_SPI_ATTRS
778         ---help---
779           This is a driver for the old NCR 53c80 series of SCSI controllers
780           on boards using memory mapped I/O. 
781           It is explained in section 3.8 of the SCSI-HOWTO, available from
782           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
783           of the box, you may have to change some settings in
784           <file:drivers/scsi/g_NCR5380.h>.
785
786           To compile this driver as a module, choose M here: the
787           module will be called g_NCR5380_mmio.
788
789 config SCSI_GENERIC_NCR53C400
790         bool "Enable NCR53c400 extensions"
791         depends on SCSI_GENERIC_NCR5380
792         help
793           This enables certain optimizations for the NCR53c400 SCSI cards.
794           You might as well try it out.  Note that this driver will only probe
795           for the Trantor T130B in its default configuration; you might have
796           to pass a command line option to the kernel at boot time if it does
797           not detect your card.  See the file
798           <file:Documentation/scsi/g_NCR5380.txt> for details.
799
800 config SCSI_IBMMCA
801         tristate "IBMMCA SCSI support"
802         depends on MCA && SCSI
803         ---help---
804           This is support for the IBM SCSI adapter found in many of the PS/2
805           series computers.  These machines have an MCA bus, so you need to
806           answer Y to "MCA support" as well and read
807           <file:Documentation/mca.txt>.
808
809           If the adapter isn't found during boot (a common problem for models
810           56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
811           option, where <pun> is the id of the SCSI subsystem (usually 7, but
812           if that doesn't work check your reference diskette).  Owners of
813           model 95 with a LED-matrix-display can in addition activate some
814           activity info like under OS/2, but more informative, by setting
815           'ibmmcascsi=display' as an additional kernel parameter.  Try "man
816           bootparam" or see the documentation of your boot loader about how to
817           pass options to the kernel.
818
819           To compile this driver as a module, choose M here: the
820           module will be called ibmmca.
821
822 config IBMMCA_SCSI_ORDER_STANDARD
823         bool "Standard SCSI-order"
824         depends on SCSI_IBMMCA
825         ---help---
826           In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
827           are assigned to the drive letters, starting with the lowest SCSI-id
828           (physical number -- pun) to be drive C:, as seen from DOS and
829           similar operating systems. When looking into papers describing the
830           ANSI-SCSI-standard, this assignment of drives appears to be wrong.
831           The SCSI-standard follows a hardware-hierarchy which says that id 7
832           has the highest priority and id 0 the lowest. Therefore, the host
833           adapters are still today everywhere placed as SCSI-id 7 by default.
834           In the SCSI-standard, the drive letters express the priority of the
835           disk. C: should be the hard disk, or a partition on it, with the
836           highest priority. This must therefore be the disk with the highest
837           SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
838           original definition of the SCSI-standard as also industrial- and
839           process-control-machines, like VME-CPUs running under realtime-OSes
840           (e.g. LynxOS, OS9) do.
841
842           If you like to run Linux on your MCA-machine with the same
843           assignment of hard disks as seen from e.g. DOS or OS/2 on your
844           machine, which is in addition conformant to the SCSI-standard, you
845           must say Y here. This is also necessary for MCA-Linux users who want
846           to keep downward compatibility to older releases of the
847           IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
848           June 1997).
849
850           If you like to have the lowest SCSI-id assigned as drive C:, as
851           modern SCSI-BIOSes do, which does not conform to the standard, but
852           is widespread and common in the PC-world of today, you must say N
853           here. If unsure, say Y.
854
855 config IBMMCA_SCSI_DEV_RESET
856         bool "Reset SCSI-devices at boottime"
857         depends on SCSI_IBMMCA
858         ---help---
859           By default, SCSI-devices are reset when the machine is powered on.
860           However, some devices exist, like special-control-devices,
861           SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
862           not reset when switched on. If you say Y here, each device connected
863           to your SCSI-bus will be issued a reset-command after it has been
864           probed, while the kernel is booting. This may cause problems with
865           more modern devices, like hard disks, which do not appreciate these
866           reset commands, and can cause your system to hang. So say Y only if
867           you know that one of your older devices needs it; N is the safe
868           answer.
869
870 config SCSI_IPS
871         tristate "IBM ServeRAID support"
872         depends on PCI && SCSI
873         ---help---
874           This is support for the IBM ServeRAID hardware RAID controllers.
875           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
876           for more information.  If this driver does not work correctly
877           without modification please contact the author by email at
878           <ipslinux@adaptec.com>.
879
880           To compile this driver as a module, choose M here: the
881           module will be called ips.
882
883 config SCSI_IBMVSCSI
884         tristate "IBM Virtual SCSI support"
885         depends on PPC_PSERIES || PPC_ISERIES
886         select SCSI_SRP_ATTRS
887         help
888           This is the IBM POWER Virtual SCSI Client
889
890           To compile this driver as a module, choose M here: the
891           module will be called ibmvscsic.
892
893 config SCSI_IBMVSCSIS
894         tristate "IBM Virtual SCSI Server support"
895         depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
896         help
897           This is the SRP target driver for IBM pSeries virtual environments.
898
899           The userspace component needed to initialize the driver and
900           documentation can be found:
901
902           http://stgt.berlios.de/
903
904           To compile this driver as a module, choose M here: the
905           module will be called ibmvstgt.
906
907 config SCSI_IBMVFC
908         tristate "IBM Virtual FC support"
909         depends on PPC_PSERIES && SCSI
910         select SCSI_FC_ATTRS
911         help
912           This is the IBM POWER Virtual FC Client
913
914           To compile this driver as a module, choose M here: the
915           module will be called ibmvfc.
916
917 config SCSI_IBMVFC_TRACE
918         bool "enable driver internal trace"
919         depends on SCSI_IBMVFC
920         default y
921         help
922           If you say Y here, the driver will trace all commands issued
923           to the adapter. Performance impact is minimal. Trace can be
924           dumped using /sys/class/scsi_host/hostXX/trace.
925
926 config SCSI_INITIO
927         tristate "Initio 9100U(W) support"
928         depends on PCI && SCSI
929         help
930           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
931           read the SCSI-HOWTO, available from
932           <http://www.tldp.org/docs.html#howto>.
933
934           To compile this driver as a module, choose M here: the
935           module will be called initio.
936
937 config SCSI_INIA100
938         tristate "Initio INI-A100U2W support"
939         depends on PCI && SCSI
940         help
941           This is support for the Initio INI-A100U2W SCSI host adapter.
942           Please read the SCSI-HOWTO, available from
943           <http://www.tldp.org/docs.html#howto>.
944
945           To compile this driver as a module, choose M here: the
946           module will be called a100u2w.
947
948 config SCSI_PPA
949         tristate "IOMEGA parallel port (ppa - older drives)"
950         depends on SCSI && PARPORT_PC
951         ---help---
952           This driver supports older versions of IOMEGA's parallel port ZIP
953           drive (a 100 MB removable media device).
954
955           Note that you can say N here if you have the SCSI version of the ZIP
956           drive: it will be supported automatically if you said Y to the
957           generic "SCSI disk support", above.
958
959           If you have the ZIP Plus drive or a more recent parallel port ZIP
960           drive (if the supplied cable with the drive is labeled "AutoDetect")
961           then you should say N here and Y to "IOMEGA parallel port (imm -
962           newer drives)", below.
963
964           For more information about this driver and how to use it you should
965           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
966           the SCSI-HOWTO, which is available from
967           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
968           you will still be able to use the parallel port for other tasks,
969           such as a printer; it is safe to compile both drivers into the
970           kernel.
971
972           To compile this driver as a module, choose M here: the
973           module will be called ppa.
974
975 config SCSI_IMM
976         tristate "IOMEGA parallel port (imm - newer drives)"
977         depends on SCSI && PARPORT_PC
978         ---help---
979           This driver supports newer versions of IOMEGA's parallel port ZIP
980           drive (a 100 MB removable media device).
981
982           Note that you can say N here if you have the SCSI version of the ZIP
983           drive: it will be supported automatically if you said Y to the
984           generic "SCSI disk support", above.
985
986           If you have the ZIP Plus drive or a more recent parallel port ZIP
987           drive (if the supplied cable with the drive is labeled "AutoDetect")
988           then you should say Y here; if you have an older ZIP drive, say N
989           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
990
991           For more information about this driver and how to use it you should
992           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
993           the SCSI-HOWTO, which is available from
994           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
995           you will still be able to use the parallel port for other tasks,
996           such as a printer; it is safe to compile both drivers into the
997           kernel.
998
999           To compile this driver as a module, choose M here: the
1000           module will be called imm.
1001
1002 config SCSI_IZIP_EPP16
1003         bool "ppa/imm option - Use slow (but safe) EPP-16"
1004         depends on SCSI_PPA || SCSI_IMM
1005         ---help---
1006           EPP (Enhanced Parallel Port) is a standard for parallel ports which
1007           allows them to act as expansion buses that can handle up to 64
1008           peripheral devices.
1009
1010           Some parallel port chipsets are slower than their motherboard, and
1011           so we have to control the state of the chipset's FIFO queue every
1012           now and then to avoid data loss. This will be done if you say Y
1013           here.
1014
1015           Generally, saying Y is the safe option and slows things down a bit.
1016
1017 config SCSI_IZIP_SLOW_CTR
1018         bool "ppa/imm option - Assume slow parport control register"
1019         depends on SCSI_PPA || SCSI_IMM
1020         help
1021           Some parallel ports are known to have excessive delays between
1022           changing the parallel port control register and good data being
1023           available on the parallel port data/status register. This option
1024           forces a small delay (1.0 usec to be exact) after changing the
1025           control register to let things settle out. Enabling this option may
1026           result in a big drop in performance but some very old parallel ports
1027           (found in 386 vintage machines) will not work properly.
1028
1029           Generally, saying N is fine.
1030
1031 config SCSI_MVSAS
1032         tristate "Marvell 88SE6440 SAS/SATA support"
1033         depends on PCI && SCSI
1034         select SCSI_SAS_LIBSAS
1035         help
1036           This driver supports Marvell SAS/SATA PCI devices.
1037
1038           To compiler this driver as a module, choose M here: the module
1039           will be called mvsas.
1040
1041 config SCSI_NCR53C406A
1042         tristate "NCR53c406a SCSI support"
1043         depends on ISA && SCSI
1044         help
1045           This is support for the NCR53c406a SCSI host adapter.  For user
1046           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
1047           in the kernel source.  Also read the SCSI-HOWTO, available from
1048           <http://www.tldp.org/docs.html#howto>.
1049
1050           To compile this driver as a module, choose M here: the
1051           module will be called NCR53c406.
1052
1053 config SCSI_NCR_D700
1054         tristate "NCR Dual 700 MCA SCSI support"
1055         depends on MCA && SCSI
1056         select SCSI_SPI_ATTRS
1057         help
1058           This is a driver for the MicroChannel Dual 700 card produced by
1059           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1060           tries to negotiate sync and uses tag command queueing.
1061
1062           Unless you have an NCR manufactured machine, the chances are that
1063           you do not have this SCSI card, so say N.
1064
1065 config SCSI_LASI700
1066         tristate "HP Lasi SCSI support for 53c700/710"
1067         depends on GSC && SCSI
1068         select SCSI_SPI_ATTRS
1069         help
1070           This is a driver for the SCSI controller in the Lasi chip found in
1071           many PA-RISC workstations & servers.  If you do not know whether you
1072           have a Lasi chip, it is safe to say "Y" here.
1073
1074 config SCSI_SNI_53C710
1075         tristate "SNI RM SCSI support for 53c710"
1076         depends on SNI_RM && SCSI
1077         select SCSI_SPI_ATTRS
1078         select 53C700_LE_ON_BE
1079         help
1080           This is a driver for the onboard SCSI controller found in older
1081           SNI RM workstations & servers.
1082
1083 config 53C700_LE_ON_BE
1084         bool
1085         depends on SCSI_LASI700
1086         default y
1087
1088 config SCSI_STEX
1089         tristate "Promise SuperTrak EX Series support"
1090         depends on PCI && SCSI
1091         ---help---
1092           This driver supports Promise SuperTrak EX series storage controllers.
1093
1094           Promise provides Linux RAID configuration utility for these
1095           controllers. Please visit <http://www.promise.com> to download.
1096
1097           To compile this driver as a module, choose M here: the
1098           module will be called stex.
1099
1100 config 53C700_BE_BUS
1101         bool
1102         depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1103         default y
1104
1105 config SCSI_SYM53C8XX_2
1106         tristate "SYM53C8XX Version 2 SCSI support"
1107         depends on PCI && SCSI
1108         select SCSI_SPI_ATTRS
1109         ---help---
1110           This driver supports the whole NCR53C8XX/SYM53C8XX family of
1111           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
1112           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1113           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1114           controllers; you need to use the Fusion MPT driver for that.
1115
1116           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1117           information.
1118
1119 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1120         int "DMA addressing mode"
1121         depends on SCSI_SYM53C8XX_2
1122         default "1"
1123         ---help---
1124           This option only applies to PCI-SCSI chips that are PCI DAC
1125           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1126
1127           When set to 0, the driver will program the chip to only perform
1128           32-bit DMA.  When set to 1, the chip will be able to perform DMA
1129           to addresses up to 1TB.  When set to 2, the driver supports the
1130           full 64-bit DMA address range, but can only address 16 segments
1131           of 4 GB each.  This limits the total addressable range to 64 GB.
1132
1133           Most machines with less than 4GB of memory should use a setting
1134           of 0 for best performance.  If your machine has 4GB of memory
1135           or more, you should set this option to 1 (the default).
1136
1137           The still experimental value 2 (64 bit DMA addressing with 16
1138           x 4GB segments limitation) can be used on systems that require
1139           PCI address bits past bit 39 to be set for the addressing of
1140           memory using PCI DAC cycles.
1141
1142 config SCSI_SYM53C8XX_DEFAULT_TAGS
1143         int "Default tagged command queue depth"
1144         depends on SCSI_SYM53C8XX_2
1145         default "16"
1146         help
1147           This is the default value of the command queue depth the
1148           driver will announce to the generic SCSI layer for devices
1149           that support tagged command queueing. This value can be changed
1150           from the boot command line.  This is a soft limit that cannot
1151           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1152
1153 config SCSI_SYM53C8XX_MAX_TAGS
1154         int "Maximum number of queued commands"
1155         depends on SCSI_SYM53C8XX_2
1156         default "64"
1157         help
1158           This option allows you to specify the maximum number of commands
1159           that can be queued to any device, when tagged command queuing is
1160           possible. The driver supports up to 256 queued commands per device.
1161           This value is used as a compiled-in hard limit.
1162
1163 config SCSI_SYM53C8XX_MMIO
1164         bool "Use memory mapped IO"
1165         depends on SCSI_SYM53C8XX_2
1166         default y
1167         help
1168           Memory mapped IO is faster than Port IO.  Most people should
1169           answer Y here, but some machines may have problems.  If you have
1170           to answer N here, please report the problem to the maintainer.
1171
1172 config SCSI_IPR
1173         tristate "IBM Power Linux RAID adapter support"
1174         depends on PCI && SCSI && ATA
1175         select FW_LOADER
1176         ---help---
1177           This driver supports the IBM Power Linux family RAID adapters.
1178           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1179           as IBM iSeries 5702, 5703, 5709, and 570A.
1180
1181 config SCSI_IPR_TRACE
1182         bool "enable driver internal trace"
1183         depends on SCSI_IPR
1184         default y
1185         help
1186           If you say Y here, the driver will trace all commands issued
1187           to the adapter. Performance impact is minimal. Trace can be
1188           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1189
1190 config SCSI_IPR_DUMP
1191         bool "enable adapter dump support"
1192         depends on SCSI_IPR
1193         default y
1194         help
1195           If you say Y here, the driver will support adapter crash dump.
1196           If you enable this support, the iprdump daemon can be used
1197           to capture adapter failure analysis information.
1198
1199 config SCSI_ZALON
1200         tristate "Zalon SCSI support"
1201         depends on GSC && SCSI
1202         select SCSI_SPI_ATTRS
1203         help
1204           The Zalon is a GSC/HSC bus interface chip that sits between the
1205           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1206           C110, J200, J210 and some D, K & R-class machines.  It's also
1207           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1208           Say Y here if you have one of these machines or cards.
1209
1210 config SCSI_NCR_Q720
1211         tristate "NCR Quad 720 MCA SCSI support"
1212         depends on MCA && SCSI
1213         select SCSI_SPI_ATTRS
1214         help
1215           This is a driver for the MicroChannel Quad 720 card produced by
1216           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1217           tries to negotiate sync and uses tag command queueing.
1218
1219           Unless you have an NCR manufactured machine, the chances are that
1220           you do not have this SCSI card, so say N.
1221
1222 config SCSI_NCR53C8XX_DEFAULT_TAGS
1223         int "default tagged command queue depth"
1224         depends on SCSI_ZALON || SCSI_NCR_Q720
1225         default "8"
1226         ---help---
1227           "Tagged command queuing" is a feature of SCSI-2 which improves
1228           performance: the host adapter can send several SCSI commands to a
1229           device's queue even if previous commands haven't finished yet.
1230           Because the device is intelligent, it can optimize its operations
1231           (like head positioning) based on its own request queue. Some SCSI
1232           devices don't implement this properly; if you want to disable this
1233           feature, enter 0 or 1 here (it doesn't matter which).
1234
1235           The default value is 8 and should be supported by most hard disks.
1236           This value can be overridden from the boot command line using the
1237           'tags' option as follows (example):
1238           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1239           4, set queue depth to 16 for target 2 and target 3 on controller 0
1240           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1241
1242           The normal answer therefore is to go with the default 8 and to use
1243           a boot command line option for devices that need to use a different
1244           command queue depth.
1245
1246           There is no safe option other than using good SCSI devices.
1247
1248 config SCSI_NCR53C8XX_MAX_TAGS
1249         int "maximum number of queued commands"
1250         depends on SCSI_ZALON || SCSI_NCR_Q720
1251         default "32"
1252         ---help---
1253           This option allows you to specify the maximum number of commands
1254           that can be queued to any device, when tagged command queuing is
1255           possible. The default value is 32. Minimum is 2, maximum is 64.
1256           Modern hard disks are able to support 64 tags and even more, but
1257           do not seem to be faster when more than 32 tags are being used.
1258
1259           So, the normal answer here is to go with the default value 32 unless
1260           you are using very large hard disks with large cache (>= 1 MB) that
1261           are able to take advantage of more than 32 tagged commands.
1262
1263           There is no safe option and the default answer is recommended.
1264
1265 config SCSI_NCR53C8XX_SYNC
1266         int "synchronous transfers frequency in MHz"
1267         depends on SCSI_ZALON || SCSI_NCR_Q720
1268         default "20"
1269         ---help---
1270           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1271           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1272           are respectively the maximum data transfer rates in mega-transfers
1273           per second for each class.  For example, a FAST-20 Wide 16 device is
1274           able to transfer data at 20 million 16 bit packets per second for a
1275           total rate of 40 MB/s.
1276
1277           You may specify 0 if you want to only use asynchronous data
1278           transfers. This is the safest and slowest option. Otherwise, specify
1279           a value between 5 and 80, depending on the capability of your SCSI
1280           controller.  The higher the number, the faster the data transfer.
1281           Note that 80 should normally be ok since the driver decreases the
1282           value automatically according to the controller's capabilities.
1283
1284           Your answer to this question is ignored for controllers with NVRAM,
1285           since the driver will get this information from the user set-up.  It
1286           also can be overridden using a boot setup option, as follows
1287           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1288           for FAST-20 synchronous data transfer (20 mega-transfers per
1289           second).
1290
1291           The normal answer therefore is not to go with the default but to
1292           select the maximum value 80 allowing the driver to use the maximum
1293           value supported by each controller. If this causes problems with
1294           your SCSI devices, you should come back and decrease the value.
1295
1296           There is no safe option other than using good cabling, right
1297           terminations and SCSI conformant devices.
1298
1299 config SCSI_NCR53C8XX_NO_DISCONNECT
1300         bool "not allow targets to disconnect"
1301         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1302         help
1303           This option is only provided for safety if you suspect some SCSI
1304           device of yours to not support properly the target-disconnect
1305           feature. In that case, you would say Y here. In general however, to
1306           not allow targets to disconnect is not reasonable if there is more
1307           than 1 device on a SCSI bus. The normal answer therefore is N.
1308
1309 config SCSI_PAS16
1310         tristate "PAS16 SCSI support"
1311         depends on ISA && SCSI
1312         select SCSI_SPI_ATTRS
1313         ---help---
1314           This is support for a SCSI host adapter.  It is explained in section
1315           3.10 of the SCSI-HOWTO, available from
1316           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1317           of the box, you may have to change some settings in
1318           <file:drivers/scsi/pas16.h>.
1319
1320           To compile this driver as a module, choose M here: the
1321           module will be called pas16.
1322
1323 config SCSI_QLOGIC_FAS
1324         tristate "Qlogic FAS SCSI support"
1325         depends on ISA && SCSI
1326         ---help---
1327           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1328           FastSCSI! cards as well as any other card based on the FASXX chip
1329           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1330
1331           This driver does NOT support the PCI versions of these cards. The
1332           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1333           SCSI support"), below.
1334
1335           Information about this driver is contained in
1336           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1337           SCSI-HOWTO, available from
1338           <http://www.tldp.org/docs.html#howto>.
1339
1340           To compile this driver as a module, choose M here: the
1341           module will be called qlogicfas.
1342
1343 config SCSI_QLOGIC_1280
1344         tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1345         depends on PCI && SCSI
1346         help
1347           Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1348
1349           To compile this driver as a module, choose M here: the
1350           module will be called qla1280.
1351
1352 config SCSI_QLOGICPTI
1353         tristate "PTI Qlogic, ISP Driver"
1354         depends on SBUS && SCSI
1355         help
1356           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1357           controllers are known under Solaris as qpti and in the openprom as
1358           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1359           driven by a different driver.
1360
1361           To compile this driver as a module, choose M here: the
1362           module will be called qlogicpti.
1363
1364 source "drivers/scsi/qla2xxx/Kconfig"
1365 source "drivers/scsi/qla4xxx/Kconfig"
1366
1367 config SCSI_LPFC
1368         tristate "Emulex LightPulse Fibre Channel Support"
1369         depends on PCI && SCSI
1370         select SCSI_FC_ATTRS
1371         help
1372           This lpfc driver supports the Emulex LightPulse
1373           Family of Fibre Channel PCI host adapters.
1374
1375 config SCSI_LPFC_DEBUG_FS
1376         bool "Emulex LightPulse Fibre Channel debugfs Support"
1377         depends on SCSI_LPFC && DEBUG_FS
1378         help
1379           This makes debugging infomation from the lpfc driver
1380           available via the debugfs filesystem.
1381
1382 config SCSI_SIM710
1383         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1384         depends on (EISA || MCA) && SCSI
1385         select SCSI_SPI_ATTRS
1386         ---help---
1387           This driver for NCR53c710 based SCSI host adapters.
1388
1389           It currently supports Compaq EISA cards and NCR MCA cards
1390
1391 config SCSI_SYM53C416
1392         tristate "Symbios 53c416 SCSI support"
1393         depends on ISA && SCSI
1394         ---help---
1395           This is support for the sym53c416 SCSI host adapter, the SCSI
1396           adapter that comes with some HP scanners. This driver requires that
1397           the sym53c416 is configured first using some sort of PnP
1398           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1399           are using isapnp then you need to compile this driver as a module
1400           and then load it using insmod after isapnp has run. The parameters
1401           of the configured card(s) should be passed to the driver. The format
1402           is:
1403
1404           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1405
1406           To compile this driver as a module, choose M here: the
1407           module will be called sym53c416.
1408
1409 config SCSI_DC395x
1410         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1411         depends on PCI && SCSI && EXPERIMENTAL
1412         ---help---
1413           This driver supports PCI SCSI host adapters based on the ASIC
1414           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1415
1416           This driver works, but is still in experimental status. So better
1417           have a bootable disk and a backup in case of emergency.
1418
1419           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1420
1421           To compile this driver as a module, choose M here: the
1422           module will be called dc395x.
1423
1424 config SCSI_DC390T
1425         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1426         depends on PCI && SCSI
1427         ---help---
1428           This driver supports PCI SCSI host adapters based on the Am53C974A
1429           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1430           PCscsi/PCnet (Am53/79C974) solutions.
1431
1432           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1433
1434           Note that this driver does NOT support Tekram DC390W/U/F, which are
1435           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1436
1437           To compile this driver as a module, choose M here: the
1438           module will be called tmscsim.
1439
1440 config SCSI_T128
1441         tristate "Trantor T128/T128F/T228 SCSI support"
1442         depends on ISA && SCSI
1443         select SCSI_SPI_ATTRS
1444         select CHECK_SIGNATURE
1445         ---help---
1446           This is support for a SCSI host adapter. It is explained in section
1447           3.11 of the SCSI-HOWTO, available from
1448           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1449           of the box, you may have to change some settings in
1450           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1451           Adaptec, and some former Trantor products are being sold under the
1452           Adaptec name.
1453
1454           To compile this driver as a module, choose M here: the
1455           module will be called t128.
1456
1457 config SCSI_U14_34F
1458         tristate "UltraStor 14F/34F support"
1459         depends on ISA && SCSI && ISA_DMA_API
1460         ---help---
1461           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1462           The source at <file:drivers/scsi/u14-34f.c> contains some
1463           information about this hardware.  If the driver doesn't work out of
1464           the box, you may have to change some settings in
1465           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1466           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1467           another driver for the same hardware: "UltraStor SCSI support",
1468           below.  You should say Y to both only if you want 24F support as
1469           well.
1470
1471           To compile this driver as a module, choose M here: the
1472           module will be called u14-34f.
1473
1474 config SCSI_U14_34F_TAGGED_QUEUE
1475         bool "enable tagged command queueing"
1476         depends on SCSI_U14_34F
1477         help
1478           This is a feature of SCSI-2 which improves performance: the host
1479           adapter can send several SCSI commands to a device's queue even if
1480           previous commands haven't finished yet.
1481           This is equivalent to the "u14-34f=tc:y" boot option.
1482
1483 config SCSI_U14_34F_LINKED_COMMANDS
1484         bool "enable elevator sorting"
1485         depends on SCSI_U14_34F
1486         help
1487           This option enables elevator sorting for all probed SCSI disks and
1488           CD-ROMs. It definitely reduces the average seek distance when doing
1489           random seeks, but this does not necessarily result in a noticeable
1490           performance improvement: your mileage may vary...
1491           This is equivalent to the "u14-34f=lc:y" boot option.
1492
1493 config SCSI_U14_34F_MAX_TAGS
1494         int "maximum number of queued commands"
1495         depends on SCSI_U14_34F
1496         default "8"
1497         help
1498           This specifies how many SCSI commands can be maximally queued for
1499           each probed SCSI device. You should reduce the default value of 8
1500           only if you have disks with buggy or limited tagged command support.
1501           Minimum is 2 and maximum is 14. This value is also the window size
1502           used by the elevator sorting option above. The effective value used
1503           by the driver for each probed SCSI device is reported at boot time.
1504           This is equivalent to the "u14-34f=mq:8" boot option.
1505
1506 config SCSI_ULTRASTOR
1507         tristate "UltraStor SCSI support"
1508         depends on X86 && ISA && SCSI
1509         ---help---
1510           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1511           adapter family.  This driver is explained in section 3.12 of the
1512           SCSI-HOWTO, available from
1513           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1514           of the box, you may have to change some settings in
1515           <file:drivers/scsi/ultrastor.h>.
1516
1517           Note that there is also another driver for the same hardware:
1518           "UltraStor 14F/34F support", above.
1519
1520           To compile this driver as a module, choose M here: the
1521           module will be called ultrastor.
1522
1523 config SCSI_NSP32
1524         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1525         depends on PCI && SCSI && !64BIT
1526         help
1527           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1528           SCSI host adapter. Please read the SCSI-HOWTO, available from
1529           <http://www.tldp.org/docs.html#howto>.
1530
1531           To compile this driver as a module, choose M here: the
1532           module will be called nsp32.
1533
1534 config SCSI_DEBUG
1535         tristate "SCSI debugging host simulator"
1536         depends on SCSI
1537         help
1538           This is a host adapter simulator that can simulate multiple hosts
1539           each with multiple dummy SCSI devices (disks). It defaults to one
1540           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1541           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1542           dummy disks are simulated, they share the same kernel RAM for 
1543           their storage. See <http://www.torque.net/sg/sdebug.html> for more
1544           information. This driver is primarily of use to those testing the
1545           SCSI and block subsystems. If unsure, say N.
1546
1547 config SCSI_MESH
1548         tristate "MESH (Power Mac internal SCSI) support"
1549         depends on PPC32 && PPC_PMAC && SCSI
1550         help
1551           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1552           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1553           other Power Macintoshes do). Say Y to include support for this SCSI
1554           adaptor.
1555
1556           To compile this driver as a module, choose M here: the
1557           module will be called mesh.
1558
1559 config SCSI_MESH_SYNC_RATE
1560         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1561         depends on SCSI_MESH
1562         default "5"
1563         help
1564           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1565           drives a bus which is entirely internal to the machine (such as the
1566           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1567           operation at up to 10 MB/s. On machines where the SCSI bus
1568           controlled by the MESH can have external devices connected, it is
1569           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1570           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1571           to disable synchronous operation.
1572
1573 config SCSI_MESH_RESET_DELAY_MS
1574         int "initial bus reset delay (ms) (0 = no reset)"
1575         depends on SCSI_MESH
1576         default "4000"
1577
1578 config SCSI_MAC53C94
1579         tristate "53C94 (Power Mac external SCSI) support"
1580         depends on PPC32 && PPC_PMAC && SCSI
1581         help
1582           On Power Macintoshes (and clones) with two SCSI buses, the external
1583           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1584           machines which only have one SCSI bus, such as the 7200, also use
1585           the 53C94. Say Y to include support for the 53C94.
1586
1587           To compile this driver as a module, choose M here: the
1588           module will be called mac53c94.
1589
1590 source "drivers/scsi/arm/Kconfig"
1591
1592 config JAZZ_ESP
1593         bool "MIPS JAZZ FAS216 SCSI support"
1594         depends on MACH_JAZZ && SCSI
1595         select SCSI_SPI_ATTRS
1596         help
1597           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1598           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1599           systems.
1600
1601 config A3000_SCSI
1602         tristate "A3000 WD33C93A support"
1603         depends on AMIGA && SCSI
1604         help
1605           If you have an Amiga 3000 and have SCSI devices connected to the
1606           built-in SCSI controller, say Y. Otherwise, say N.
1607
1608           To compile this driver as a module, choose M here: the
1609           module will be called a3000.
1610
1611 config A2091_SCSI
1612         tristate "A2091/A590 WD33C93A support"
1613         depends on ZORRO && SCSI
1614         help
1615           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1616           say N.
1617
1618           To compile this driver as a module, choose M here: the
1619           module will be called a2091.
1620
1621 config GVP11_SCSI
1622         tristate "GVP Series II WD33C93A support"
1623         depends on ZORRO && SCSI
1624         ---help---
1625           If you have a Great Valley Products Series II SCSI controller,
1626           answer Y. Also say Y if you have a later model of GVP SCSI
1627           controller (such as the GVP A4008 or a Combo board). Otherwise,
1628           answer N. This driver does NOT work for the T-Rex series of
1629           accelerators from TekMagic and GVP-M.
1630
1631           To compile this driver as a module, choose M here: the
1632           module will be called gvp11.
1633
1634 config SCSI_A4000T
1635         tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
1636         depends on AMIGA && SCSI && EXPERIMENTAL
1637         select SCSI_SPI_ATTRS
1638         help
1639           If you have an Amiga 4000T and have SCSI devices connected to the
1640           built-in SCSI controller, say Y. Otherwise, say N.
1641
1642           To compile this driver as a module, choose M here: the
1643           module will be called a4000t.
1644
1645 config SCSI_ZORRO7XX
1646         tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
1647         depends on ZORRO && SCSI && EXPERIMENTAL
1648         select SCSI_SPI_ATTRS
1649         help
1650           Support for various NCR53c710-based SCSI controllers on Zorro
1651           expansion boards for the Amiga.
1652           This includes:
1653             - the Amiga 4091 Zorro III SCSI-2 controller,
1654             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1655               (info at
1656               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1657             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1658               accelerator card for the Amiga 1200,
1659             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1660
1661 config ATARI_SCSI
1662         tristate "Atari native SCSI support"
1663         depends on ATARI && SCSI
1664         select SCSI_SPI_ATTRS
1665         select NVRAM
1666         ---help---
1667           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1668           Falcon, ...) say Y to get it supported. Of course also, if you have
1669           a compatible SCSI controller (e.g. for Medusa).
1670
1671           To compile this driver as a module, choose M here: the
1672           module will be called atari_scsi.
1673
1674           This driver supports both styles of NCR integration into the
1675           system: the TT style (separate DMA), and the Falcon style (via
1676           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1677           in the Hades (without DMA).
1678
1679 config ATARI_SCSI_TOSHIBA_DELAY
1680         bool "Long delays for Toshiba CD-ROMs"
1681         depends on ATARI_SCSI
1682         help
1683           This option increases the delay after a SCSI arbitration to
1684           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1685           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1686           would impact performance a bit, so say N.
1687
1688 config ATARI_SCSI_RESET_BOOT
1689         bool "Reset SCSI-devices at boottime"
1690         depends on ATARI_SCSI
1691         help
1692           Reset the devices on your Atari whenever it boots.  This makes the
1693           boot process fractionally longer but may assist recovery from errors
1694           that leave the devices with SCSI operations partway completed.
1695
1696 config MAC_SCSI
1697         bool "Macintosh NCR5380 SCSI"
1698         depends on MAC && SCSI=y
1699         select SCSI_SPI_ATTRS
1700         help
1701           This is the NCR 5380 SCSI controller included on most of the 68030
1702           based Macintoshes.  If you have one of these say Y and read the
1703           SCSI-HOWTO, available from
1704           <http://www.tldp.org/docs.html#howto>.
1705
1706 config SCSI_MAC_ESP
1707         tristate "Macintosh NCR53c9[46] SCSI"
1708         depends on MAC && SCSI
1709         select SCSI_SPI_ATTRS
1710         help
1711           This is the NCR 53c9x SCSI controller found on most of the 68040
1712           based Macintoshes.
1713
1714           To compile this driver as a module, choose M here: the module
1715           will be called mac_esp.
1716
1717 config MVME147_SCSI
1718         bool "WD33C93 SCSI driver for MVME147"
1719         depends on MVME147 && SCSI=y
1720         select SCSI_SPI_ATTRS
1721         help
1722           Support for the on-board SCSI controller on the Motorola MVME147
1723           single-board computer.
1724
1725 config MVME16x_SCSI
1726         tristate "NCR53C710 SCSI driver for MVME16x"
1727         depends on MVME16x && SCSI
1728         select SCSI_SPI_ATTRS
1729         help
1730           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1731           SCSI controller chip.  Almost everyone using one of these boards
1732           will want to say Y to this question.
1733
1734 config BVME6000_SCSI
1735         tristate "NCR53C710 SCSI driver for BVME6000"
1736         depends on BVME6000 && SCSI
1737         select SCSI_SPI_ATTRS
1738         help
1739           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1740           SCSI controller chip.  Almost everyone using one of these boards
1741           will want to say Y to this question.
1742
1743 config SUN3_SCSI
1744         tristate "Sun3 NCR5380 SCSI"
1745         depends on SUN3 && SCSI
1746         select SCSI_SPI_ATTRS
1747         help
1748           This option will enable support for the OBIO (onboard io) NCR5380
1749           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1750           "Sun3" type VME scsi controllers also based on the NCR5380.
1751           General Linux information on the Sun 3 series (now discontinued)
1752           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1753
1754 config SUN3X_ESP
1755         bool "Sun3x ESP SCSI"
1756         depends on SUN3X && SCSI=y
1757         select SCSI_SPI_ATTRS
1758         help
1759           The ESP was an on-board SCSI controller used on Sun 3/80
1760           machines.  Say Y here to compile in support for it.
1761
1762 config SCSI_SUNESP
1763         tristate "Sparc ESP Scsi Driver"
1764         depends on SBUS && SCSI
1765         select SCSI_SPI_ATTRS
1766         help
1767           This is the driver for the Sun ESP SCSI host adapter. The ESP
1768           chipset is present in most SPARC SBUS-based computers and
1769           supports the Emulex family of ESP SCSI chips (esp100, esp100A,
1770           esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
1771
1772           To compile this driver as a module, choose M here: the
1773           module will be called sun_esp.
1774
1775 config ZFCP
1776         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1777         depends on S390 && QDIO && SCSI
1778         select SCSI_FC_ATTRS
1779         help
1780           If you want to access SCSI devices attached to your IBM eServer
1781           zSeries by means of Fibre Channel interfaces say Y.
1782           For details please refer to the documentation provided by IBM at
1783           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1784
1785           This driver is also available as a module. This module will be
1786           called zfcp. If you want to compile it as a module, say M here
1787           and read <file:Documentation/kbuild/modules.txt>.
1788
1789 config SCSI_SRP
1790         tristate "SCSI RDMA Protocol helper library"
1791         depends on SCSI && PCI
1792         select SCSI_TGT
1793         help
1794           If you wish to use SRP target drivers, say Y.
1795
1796           To compile this driver as a module, choose M here: the
1797           module will be called libsrp.
1798
1799 endif # SCSI_LOWLEVEL
1800
1801 source "drivers/scsi/pcmcia/Kconfig"
1802
1803 source "drivers/scsi/device_handler/Kconfig"
1804
1805 endmenu